Instruction Manual
HI 2209 • HI 22091
Bench pH Meters
www.hannainst.com
Question and Answer IconNeed help?

Do you have a question about the Hanna Instruments HI 2209 and is the answer not in the manual?

Hanna Instruments HI 2209 Specifications

General IconGeneral
ModelHI 2209
DisplayLCD
pH Range-2.00 to 16.00 pH
pH Resolution0.01 pH
pH Accuracy±0.01 pH
mV Accuracy±0.2 mV
Temperature Resolution0.1°C (0.1°F)
Temperature Accuracy±0.4°C (±0.8°F)
pH CalibrationUp to 5 points
LoggingYes
Power Supply12 VDC adapter (included)
Environment0 to 50°C (32 to 122°F); RH max 95% non-condensing
ElectrodeNot included
mV Range±2000 mV
mV Resolution0.1 mV
Temperature Range-20.0 to 120.0 °C
Temperature CompensationAutomatic
Input Impedance10^12 ohms
CalibrationAutomatic/Manual

Summary

WARRANTY

FUNCTIONAL DESCRIPTION

SPECIFICATIONS

OPERATIONAL GUIDE

TAKING PH MEASUREMENTS

Step-by-step process for performing accurate pH measurements with the instrument.

TAKING ORP MEASUREMENTS

AFTER MEASUREMENTS

pH CALIBRATION

PREPARATION

Steps for preparing buffer solutions and equipment before pH calibration.

PROCEDURE

Detailed steps for performing the pH calibration process on the meter.

pH BUFFER TEMPERATURE DEPENDENCE

ELECTRODE CONDITIONING AND MAINTENANCE

PREPARATION PROCEDURE

Instructions for initial electrode setup and conditioning before first use.

MEASUREMENT

Guidance on handling and rinsing the electrode tip during measurements.

STORAGE

Proper methods for storing the electrode to maintain its performance and lifespan.

PERIODIC MAINTENANCE

Regular checks and upkeep required for the electrode and its cable.

CLEANING PROCEDURE

General

General soaking procedure for cleaning the electrode.

TROUBLESHOOTING

Noise

Diagnosing and resolving issues causing fluctuating readings.

Dry MembraneJunction

Troubleshooting steps for electrodes with dry membrane or junction.

Drifting

Addressing issues where readings gradually change over time.

Low Slope

Identifying causes and solutions for a low slope during calibration.

No Slope

Troubleshooting when no slope is detected during calibration.

Slow ResponseExcessive Drift

Resolving slow electrode response times and significant drift.

TEMPERATURE CORRELATION FOR pH SENSITIVE GLASS

PH ELECTRODES

ORP ELECTRODES

ELECTRODE APPLICATION REFERENCE GUIDE

RECOMMENDATIONS FOR USERS

Related product manuals