EasyManua.ls Logo

Harman Absolute 43 - Power Loss and Ignition Procedures; Minimizing Smoke During Power Loss; Emergency Manual Ignition

Harman Absolute 43
22 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Harman® • Absolute43 Owner’s Manual_R2 • 2015 -___ • 03/1520
3-90-777000c
C. Loss of Power
Minimizing Smoke During Loss of Power Using Battery
Back-up
Harman® strongly recommends installing battery back-
up to minimize entry of smoke into the room in the
event of power loss.
Your pellet/biomass burning appliance relies on a
combustion blower to remove exhaust. A power failure will
cause the combustion blower to stop. This may lead to
exhaustseepingintotheroom.Verticalriseintheventing
may provide natural draft. It is, however, no guarantee
against leakage.
There are two Harman® approved battery back-up
options for your appliance:
Uninterruptible Power Supply UPSbatteryback-upsare
availableonlineoratcomputerandofceequipmentstores.
Your Harman® appliance with Rev E or later software
available beginning in November 2010 may be plugged
directlyintoaHarman®approvedUPS:
• The APC (American Power Conversion) model
#BE750GandtheTrippLitemodelINTERNET750Uare
testedandapproved.Otherbrandsormodelsmaynot
be compatible.
Whenpowerislost,afullychargedUPSwillpowerasafe,
combustion blower only shut-down. Your appliance will
pulse the blower every few seconds to clear exhaust until
thereisout. NOTE: The UPS provides safe shut-down
only. It is not intended for continued operation.
• TheSurere512connectstoa12voltdeepcyclebattery
thatwill runyourappliance forupto eight(8)hours. It
includes a trickle charge feature that keeps your battery
chargedwhenpowerisavailable.NOTE:Ifthepoweris
outforlongerthanbatterylife,smokeleakagemaystill
occur unless your stove has been safely shut down.
Yourappliancewillrecognizewhenpowerisrestored.What
happens depends on ESP temperature and whether it is
equipped with automatic ignition:
In “Automatic” Mode,unitsequipped with automatic
ignitionwillrespondtothesetpointandESPtemperature
and resume normal operation.
• In “Idle” Mode,orforunitswithoutautomaticignition:
• If the ESP is cool, the appliance will remain shut
down.
• IfthereisoutandtheESPisstillwarm,thefeeder
mayrestart.Sincethereisout,theESPtemperature
willnotrise.Theunitwillthenshut-down,andmay
ashasix-blinkstatuserror.(SeeESPerrorcodes)
• If the re is still burning, it will resume normal
operation.
Contact your dealer if you have questions about UPS
compatibility with your appliance.
Use only Harman
®
approved battery back-up devices.
Other products may not operate properly, can create
unsafe conditions or damage your appliance.
CAUTION
!
Always keep appliance doors and hopper lid closed
and latched during operation and during power
failures to minimize risk of smoke or burn-back.
D. Emergency Manual Ignition
Harman
®
pellet stoves and inserts should be lit using the
automatic ignition system. This is the safest and most
reliablewayforignitingtheunit.Intheeventtheautomatic
igniterisnotfunctioning,thestepsbelowmaybefollowed
tomanuallylightthestoveorinsertinthe“ConstantBurn”
mode. Manual lighting is for emergency purposes only,
and the igniter should be repaired or replaced as soon as
practical.
WARNING
!
Only use restarter commercially marketed for pellet
stoves and inserts, including wax coated wood chips,
pellet starter gel and pellet igniter blocks. Use of any
othertypeofrestarterisprohibited.
To avoid serious injury or death read and follow
manufacturer’swarningandinstructionsforuseofrestarter.
Useofrestarterisonlypermittedwhenperformingacold
start.
Neverattempt to manually light a stove or insert thathas
been operated recently and is not at room temperature.
If automatic ignition was attempted, be sure to give the
stove or insert at least 30 minutes or longer to cool to room
temperature.
Be sure that the stove or insert is in the “Constant Burn”
mode of operation.
Once all the precautions have been taken, follow these
steps:
1.On the touch control, select the Burn Mode icon then
select“ConstantBurn”.
2. ArrowbackandselecttheIgnitericonthenselect“Manual”
fortheignitionmethod.SelecttheHomeIcontogoback
totheMainMenu.
3.Fillburnpotwithpellets,onlyhalfway.(DoNotOverFill).
4.Add firestarter to pellets following manufacturer’s
instructions.
5.Lightpelletgelwithamatch,andclosethedoor,touch
theOn/Officononthehomescreen.Operationwillbegin
whentherereachesthepropertemperature.
WARNING
!