pg. 26
INPUT PWR Connector
The MU-1300, MU-2300 and MU-3300 controllers feature a 2-pin 3.5 mm Phoenix connector with screw retention for
providing DC power to the controller. The suggested power supply for the MU-series controllers is a 13.5 VDC 6.6 A
output, suitable for 50° C.
Preparing Captive Wires
You will need a wire stripper and flat-blade screwdriver to prepare and connect the captive wires.
NOTE: Never pre-tin wires for compression-type connections.
1. Strip 0.25 inch (6.35mm) of insulation off all wires.
2. Insert each wire into the appropriate opening on the connector (according to the wiring diagrams and connector
types described in this section).
3. Tighten the screws to secure the wire in the connector. Do not tighten the screws excessively, as doing so may
strip the threads and damage the connector.
ID Pushbutton
All MU-series controllers feature an ID pushbutton which you can use to reset the default settings on the controller or
restore the controller to its factory firmware image. The Status LED will indicate the action performed by changing
color.
The ID Pushbutton functionality is as follows:
ID Button Hold Duration
Status LED color
Function Performed on Release
Not held
Green, blinking if scripts are running
Running normally
0 10 seconds
White, fast blinking
Running normally, ID broadcast sent
10 20 seconds
Amber, fast blinking
Configuration Reset (see below)
20 + seconds
Red, fast blinking
Factory Firmware Reset (see below)
A configuration reset performs the following operations:
All user scripts (Python, Groovy, JavaScript and Node-RED) and libraries are deleted
All manually installed extensions are uninstalled
All manually configured repositories are removed
All device instance files are removed
All Plug-in configuration items are reset to their defaults
All SMTP servers are removed
ICSP authentication/encryption returns to "off"
All bound NDP devices are unbound (TBD)
All IRL files are removed
All installed HiQnet AudioArchitect files are removed
HiQnet node id returns to default
All Duet module .jar files are removed
Network configuration is returned to defaults
LAN returns to DHCP client mode, hostname returns default value
ICSLan returns to DHCP Server mode on octets 198.18.0.x
802.1x is disabled
Network time is disabled
NTP servers are cleared
Time will coast using the real-time clock

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Harman AMX MU Series and is the answer not in the manual?

Harman AMX MU Series Specifications

General IconGeneral
BrandHarman
ModelAMX MU Series
CategoryController
LanguageEnglish

Related product manuals