Harman® • P-Series Installation Manual_R3 • 2014 -___ • 09/1421 3-90-436168i
5
Appliance Set-Up
Figure 5.1
A. Unpacking
TheP-Seriesisbolted(1/4x1"hexheadbolts)totheskid
topreventmovementduringshipping.
Tofreethestovefromtheskidyoumustremovethehold-
downboltsintherearofthepedestalbaseusinga7/16”
socketorwrench.Figure5.1.
B. Removing Rear Cover Panels
Therearcoverpanelsaresecuredtothestovewiththree
screwseach.Twoofthescrewsneedonlybeloosened,not
removed,toremovethepanels.Itisrecommendedthatthe
rearcoversareinstalledusinga5/16”socket,wrenchornut
driveraftertheunitisinplaceandtheventpipeisinstalled,
topreventcontactwithhotormovingparts.
Ifneeded,installthe(2)5/16-18X3/4”levelingboltslocated
inthehardwarekit.Figure5.1.
C. Firebrick
The P43 Pellet Stove has a single (1) rebrick that gets
installedhorizontallyontheanglebracketabovetheburnpot.
TheP61AandP68havethree(3)rebrickthatgetinstalled
verticallyontheanglebracket.Figure5.2.
D. Flame Guide
Installthecastironameguideontopoftheburnpot.Make
surethattheameguideisfullyseatedontheverticalsides
oftheburnpotandthatthebackoftheguiderestsagainst
thebodyofthestove.Figure5.3.
INSTALLEXHAUSTVENTATCLEARANCESSPECIFIED
BYTHEMANUFACTURER.Mostpelletventpiperequiresa
minimumof1"ofclearancetocombustiblematerialsalthough
somecanbeinstalledat1"clearance.
Followtheseinstructionsalongwithalllocalcodesregarding
installationofthisappliance.
Do NOT use makeshift compromises when installing this
appliance,seriousconsequencesmayresult.
Withanyhearthappliance,installationofsmokedetectors
isrecommendedoneverylevelofthehome.
Possible causes of smoke detector activation:
Paintcuringprocess-Openawindowneartheappliance
fortherstfewhoursofburning.
Exhaustbeingdrawnbackinsidethedwelling-Outsideair
connectiontotheapplianceisnecessary.
Ventleakage-Allinteriorseamsandjointsshouldbesealed
withsiliconewhereapplicable.Followventmanufacturers
instructionsforpropersealing.
RearCover
Panel
Shipping Bolts
Note:Thesesameholesareusedfor
securing the stove in mobile home
installation.
RearCover
Panel
Figure 5.2
1 Firebrick
Figure 5.3
Flame guide
3 Firebrick
P43 Pellet Stove
P61A & P68
Pellet Stove
Leveling Bolt
Leveling Bolt