EasyManua.ls Logo

Harman P43 - Glass Maintenance

Harman P43
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Harman® • P-Series Owner’s Manual_R1 • 03/1417 3-90-436168c
F. Manual Ignition (Continued)
TheP-SeriesPelletStoveiscapableofmanualoperation.
Thisalsoallowstheoperatortomanuallycontroloperation
duringanemergency(i.e.igniterfailure,whenusinga512H
batterybackup,orwhenusingcertaingenerators.)
Theunitcanbeswitchedbetween"AUTO"and"MANUAL"
atanytimeduringoperation.
Igniter Switch to "MANUAL"
Room Temperature Mode
Therewillhavetobelitwithstartinggelandamatch,or
started automatically, see "Automatic Operation". Turnto
"Manual"positiononcethestartcyclebegins.
Thedifferencebetween"AUTO"RoomTemperatureMode
and"Manual"RoomTemperatureModeisthattherewillnot
gooutastheroomtemperaturegoesabovethecontrolboard
setting.Theunitcanonlygotolowburnandwillremainthere
untilitrunsoutoffueloruntilmoreheatisneededandthe
feedrateincreases.Feedrateadjustmentsanddialsettings
arethesameas"AUTO"settings.
Igniter Switch to "MANUAL"
Constant burn Mode
Theadvantageofthismodeistoallowtheoperatortohave
alargeviewingrewithoutblowingextraheatintotheroom.
Duringoperation,withthetemperaturedialsetat#4orless,
thedistributionfanwillnotoperate.A#4onthetemperature
dialanda#4onthefeedlimitisapproximately80%output.
Itisnotnecessarytooperatethedistributionblowerbelow
this point. Therefore, there can be a higher feed rate (a
largerviewingre)withoutanexcessofhotairblowinginto
theroom.
AnexampleofwhentousetheManualConstantburnMode
isifyouwanttowatchalargereandtheroomisalreadyup
totemperature.TheConstantburnModeallowsyoutohave
alargerreandalowersoundlevel,withoutthedistribution
blower.
NOTE: During the use of this mode, if you keep increasing
the temperature dial setting to increase the re size, the
distribution blower will automatically come on when the
ESP Temperature reaches 350
°
F, or 81% output.
NOTE: When starting the unit in the "AUTO" mode
and switching to "MANUAL", you may switch at any
time. Once an ignition cycle is started, it will continue
regardless of mode.
Room Temperature Mode: This setting will produce a room temperature
of 70 degrees with the distribution blower at medium speed.
Thissettingwillproducealargeviewingrewithoutadistribution
blower operating.
Manual Constant burn Mode

Other manuals for Harman P43

Related product manuals