Calibration fluid outdated or
dirty
Replace calibration fluid
Probe left dry for a long time
Leave probe in pool water for
24 hours, and recalibrate
Device goes into alarm : pH too
high.
Verify pH with color method.
Manually correct pH or disable
the alarm function once and let
the dosing device reduce pH.
Device goes into alarm : pH too
low
Verify pH with color method.
Manually correct pH or disable
the alarm function once and let
the dosing device reduce pH.
Use pH+ once and set setting
device to pH+.
pH always 7, also in calibration
liquids pH 4 and pH 9.
Replace pH probe and re-
calibrate
Device comes in alarm : Rx too
low
Rx < 150. Impurities in pool
water
Temporarily switch to manual
addition of chlorine. Check
chlorine via color measurement.
Chlorine container is empty
Replace chlorine container
Rx gives a very different value
compared to table 1
Disturbing impurity in the water
Turn off chlorine dosing, and
add the chlorine manually
(temporarily)
Electromagnetic interference
Acid pump does not dosing
Switch under the dosing pump
is on "O"
Settings of pH scheme are
wrong : pH+ while pH is dosed
(or vice versa)