A level detector is attached that
gives incorrect contact
A flow siwtch is connected and
it indicates that there is no flow
Verify flow and flow switch (go
to setting flow switch : no)
Acid pump continues to dosing
Wrong parameter set : pH+
while pH is dosed (or vice versa)
Relay on circuit board lingers
Acid pump only caps the
occasional
Acid pump is on proportinal
dosing
Chlorine pump does not dosing
Switch under the dosing pump
is on "O"
Settings of Rx scheme are wrong
A level detector is attached that
gives incorrect contact
A flow siwtch is connected and
it indicates that there is no flow
Verify flow and flow switch (go
to setting flow switch : no)
Chlorine pump continues to
dosing
Check settings and verify
chlorine content met with color
method.
Relay on circuit board lingers
Acid pump and chlorine pump
do not pump.
A flow siwtch is connected and
it indicates that there is no flow
Verify flow and flow switch (go
to setting flow switch : no)
There are level detectors
attached that give a wrong
contact
Chlorine or acid pump does not
suck up liquid
Barrel is empty or suction foot
hangs above liquid level
Replace acid or chlorine
container; Lower suction foot.
Replace suction foot
ZWMX2205-Z
Peristaltic hose is leaking
Replace peristaltic hose
ZWMX2231-Z
Injection nozzle is clogged
Replace injection nozzle
ZWMX2220-Z