47
Test Options (2)
R BAT VULOS TON VINSON CT
OPTIONAL TESTS
TO SCROLL / ENT TO CONT
GPS
OPTIONAL TESTS
WIDEBAND TESTS
R BAT VULOS TON VINSON CT
WIDEBAND TESTS
TO SCROLL / ENT TO CONT
TX RX
R BAT VULOS TON VINSON CT
SELECT TX OR RX
TO SCROLL / ENT TO CONT
TX
R BAT VULOS TON VINSON CT
SELECT RF PATH
TO SCROLL / ENT TO CONT
HIGHBAND
R BAT VULOS TON VINSON CT
BANDWIDTH
TO SCROLL / ENT TO CONT
5000 KHz
R BAT VULOS TON VINSON CT
TX FREQUENCY (MHz)
ENTER 227.500 TO 1997.500
0227.5000
R BAT VULOS TON VINSON CT
TX PWR, dB FROM FULL
ENTER 0 TO 13
00
Select OPTIONAL TESTS to run a test on the GPS or Receiver Exciter
Synthesizer (RES) Flash. Both tests take 3 to 8 minutes each to run. Either
TEST PASSED or a fault will be displayed.
WIDEBAND TESTS test the ANW2 portion of the radio. There are 4 choices
under WIDEBAND TESTS: TX RX allows the operator to run transmit and
receive tests. RX SENSITIVITY allows the operator to run only the receiver
sensitivity test. TX POWER runs only the transmit power test. TX frequency
runs only the transmit frequency sensitivity test.
Shown above are some of the Wideband Tests screens. After TX RX Wideband
test is selected, then either TX or RX must be selected. The RF PATH is either
HIGHBAND OR LOWBAND. BANDWIDTH is 5000 KHz, 2500 KHZ, or 1250
KHz. TX FREQUENCY is 227.500 MHz to 1997.500 MHz. Tx power is selected
in dB down from HIGH Power. 0 dB is full power (5 Watts) and 13 dB down is the
lowest (0.25 Watt). If running a RX test, TEST DURATION (SECS) 1 to 600
seconds must be selected. Then select YES or NO to RUN TEST. When the
tests are complete, use the up/down arrows to scroll through the results.