EasyManua.ls Logo

Harris Platinum Series - Page 21

Default Icon
158 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Distortion (THD) 50 Hz to 15 kHz: 0.25% or less.
15 kHz to 50 kHz: 0.75% or less.
Distortion (IMD): 0.5% or less. SMPTE 4:1 test signal.
Stereo Separation 50 Hz to 15 kHz: 45 dB or better. Equivalent mode (uncompanded).
Crosstalk 50 dB or better. Stereo or Main channel into SAP.
3. SCA (2 inputs)
Level: 1 volt RMS, adjustable.
Impedance: 75 Ohms, unbalanced.
Frequency Response 20 Hz - 110 kHz:
+0.5 dB.
3. Service Conditions
Environmental Requirements
Operating Ambient Temperature Range: 0° to +50°C(+32° to +122°F). Derate 2°C per 1,000 feet (305 m) above
sea level.
Altitude: 0 to 10,000 feet (3,084 meters) above sea level.
Ambient Humidity: 0 to 95% relative humidity, non-condensing.
Power Requirements
Input: 208/240 volts
+10%, 3-phase, 50/60 Hz or
380/415 volts
+10%,3-phase,50Hz.
Single-phase optional on 1 kW, 2 kW.
Regulation:
+10% or better, no load to full load.
Phase Unbalance:
+3% maximum.
Air System Requirements
Inlet Air Openings: Rear doors.
Exhaust Air Openings: Each amplifier cabinet top, approx. 34" x 24".
Exhaust Temperature: 10°C maximum temperature rise above inlet.
Allowable Back Pressure: -0.25" H
2
O at each cabinet exhaust stack.
Table 1-1. Specifications (Continued)
Section I - Introduction
888-2365-001 1-9
WARNING: Disconnect primary power prior to servicing.

Table of Contents