4. EXC A FAULT: ON = Exciter A is in a Fault condition
5. EXC B FAULT: ON = Exciter B is in a Fault condition
6. SPARE 1:
7. SPARE 2:
8. SPARE 3:
9. SPARE 4:
10.VIS AGC EN: ON = Visual AGC is enabled
11.AUR AGC EN: ON = Aural AGC is enabled
12.UNUSED 010b:
13.PFAIL: ON = Monitor has detected an impending
power failure
14.WDOGFAIL: ON = Monitor Watchdog timer has ex-
pired
15.AD STATUS: ON = Analog to Digital Converter has
conversion failure
16.UNUSED 010f:
6.8 Slave Raw Data Screen Information
The same information is reported for all active slave cabinets on
this screen. Each Column containing a cabinets information is
headed by a cabinet designator:
AURA: Aural Cabinet A
AURB: Aural Cabinet B
VISA:VisualCabinetA
VISB:VisualCabinetB
VISC:VisualCabinetC
VISD:VisualCabinetD
NOTE
(Not all cabinets present in all configurations.)
The information presented for each cabinet is:
AIRF: 1 = Air Fault
DORF: 1 = Door Fault
PS1F: 1 = Power Supply 1 Fault
PS2F: 1 = Power Supply 2 Fault
SPAR1: Spare
SPAR2: Spare
SPAR3: Spare
TXD: 1 = Cabinet is OFF
MODF:ThisisaHexadecimalnumber witheachbit ofeach
hex digit corresponding to a module slot in the cabinet. The
low order bit of the low order digit refers to slot one, the
next high order bit refers to slot two, and so on up to slot
17. A bit equal to one means that the module in the refer-
enced slot has a fault. See Figure 6-1 and Table 6-1.
ID: This is the hexadecimal representation of the cabinet
address as entered in the DIP switches on the Slave Con-
troller. RF1: Peak Detector 1 Output Voltage
RF2: Peak Detector 2 Output Voltage
RF3: Peak Detector 3 Output Voltage
RF4: Peak Detector 4 Output Voltage
RF5: Peak Detector 5 Output Voltage
RF6: Peak Detector 6 Output Voltage
PS1V: Power Supply 1 Voltage Output Monitor voltage
PS1A: Power Supply 1 Current Output Monitor voltage
PS2V: Power Supply 2 Voltage Output Monitor voltage
PS2A: Power Supply 2 Current Output Monitor voltage
Figure 6-1. PA Cabinet
Module Slot Numbers
Section VI - Troubleshooting
888-2365-001 6-3
WARNING: Disconnect primary power prior to servicing.