Alarms Full Description - This screen is displayed by using the
DESC key from the Systems Alarms screen. This screen displays
a more detailed description of the alarm.
The summary alarms screen displays a description and short
alarm indication. The detail screen provides more detailed infor-
mation on the nature of the alarm, along with the summary alarm
for clarification.
There are 5 active softkeys on this screen. They are:
DOWN - This keymovesthe cursor downthrough the alarms list.
UP - This key moves the cursor up through the alarms list.
DELETE - This key will delete the selected alarm, IF and only
IF the alarm is inactive.
LIST - This key will display the Summary Alarms screen.
EXIT - This key will return the user to the Bargraph Meter screen.
SystemAlarms - This screen is displayed by using the ALARM
key while viewing the Bargraph Meter screen.
This screen displays the summary alarms queue. This informa-
tion displays the Fault that occurred, the time and date. An
A
indicates alarm is still activeand cannot be deleted. An
I indicates
an alarm that has now returned to normal and may be deleted or
retained in memory for future reference.
In the left column alarms are numbered sequentially (001-999)
as they are picked up in memory. Numbering will start over after
1000 events. A monitor reset will cause counting to start again at
001.
There are 5 active softkeys on this screen. They are:
DOWN - This key moves the cursor down through the alarms list
and is indicated by the cursor arrow.
UP - This key moves the cursor up through the alarms list and is
indicated by the cursor arrow.
DELETE - This key will delete the selected alarm, IF and only
IF the alarm is inactive.
DESC - This key will display the Detailed Alarms screen. The
information for the selected alarm will be displayed in a detailed
format.
EXIT- This keywill return theusertotheBargraphMeterscreen.
SYSTEM ALARMS
>024 VPA A Slave Fault
025 VPA B Slave Fault
027 Visual VSWR Overld
037 Visual VSWR Overld
038 Visual VSWR Overld
039 Aural VSWR Overld
040 VPA A Slave Fault
041 VPA B Slave Fault
042 Brownout Condition
043 Brownout Condition
27-OCT 12:00 I
27-OCT 12:00 I
27-OCT 12:00 I
27-OCT 12:00 I
27-0CT 12:00 I
27-0CT 12:00 A
27-0CT 12:00 A
27-0CT 12:00 I
27-OCT 12:00 I
27-0CT 12:00 I
DELETE DESC EXIT
Figure 3-17. System Alarms
ALARMS FULL DESCRIPTION
>042 Brownout Condition 27-OCT 12:00 I
Alarm is INACTIVE and can be deleted
A Low AC Voltage Condition was Sensed
at 12:00 on 27-OCT-89
DELETE LIST EXIT
Figure 3-18. Alarms Full Description
3-12 888-2365-001 Rev. B: 1/11/1999
WARNING: Disconnect primary power prior to servicing.