16
kW
mm
2
A
4.5
1 2 3 4
U2 N
L1 L2 L3
L1
N
220V-230V 1N~
NN UW
6.0
V
K1
PE
3 x 4
20
GND
3
3 x 6
3
25
6
1 N~
230V
1 2
C150
3
4
5
ntc
-t
JUNCTION BOX
KLEMMDOSE
YELLOW/GELB
RED/ROT
BLUE/BLAU
WHITE/WEIß
Figure 11a. Single-phase electrical connections of
BC45E and BC60E heater
Abbildung 11a. Einphasiger Elektroanschlüsse des BC45E
und BC60E Saunaofens
400V/230V 3N~
PE
5
3 x 1,5 mm
2
BC45E
BC60E
BC80E
L3
N
BC90E, BC80E
L1
L2
L2
L1
N
5
1 2 3 4
U2 N L1 L2 L3N K2N UW V K1
3 x 1,5 mm
2
5
L3
BC60E, BC45E
(SSJ)
BC90E
4 x 0,5 mm
2
A
ntc
-t
C90
max. 100 W
CONTROL UNIT
STEUERGERÄT
CONTROL OF
HEATING
STEUERUNG
DES ERHITZENS
SIGNAL LIGHT
KONTROLLAMPE
HEATER
SAUNAOFEN
FUSES
SICHERUNGEN
LIGHT
LICHT
max. 100 W
HEATER
SAUNAOFEN
POWER SUPPLY
HAUPTZENTRALE
SENSOR
FÜHLER
JUNCTION BOX
KLEMMDOSE
YELLOW/GELB
RED/ROT
BLUE/BLAU
WHITE/WEIß
N
L1 L2 L3
400V/230V 3N~
5
5
L3
L2
L1
N
C150
1 2 3 4
N
L1NN UW V
PE
L2 L3
U2
K1
5
ntc
-t
4 x 0.5 mm
2
CONTROL OF
HEATING
STEUERUNG
DES ERHITZENS
LIGHT
LICHT
max. 100 W
JUNCTION BOX
VERTEILERDOSE
HEATER
SAUNAOFEN
SENSOR
FÜHLER
FUSES
SICHERUNGEN
POWER SUPPLY
HAUPTZENTRALE
3 x 1.5 mm
2
(SSJ)
YELLOW/GELB
RED/ROT
BLUE/BLAU
WHITE/WEIß
Figure 11b. 3-phase electrical connections of control
unit C150 and BCE-heater
Abbildung 11b. 3-phasiger Elektroanschlüsse das
Steuergerät C150 und des
Saunaofens BCE
Figure 11c. 3-phase electrical connections of
control unit C90 and BCE-heater
Abbildung 11c. 3-phasiger Elektroanschlüsse
das Steuergerät C90 und des
Saunaofens BCE
Figure 12. Reset button for overheat protector