Faults 2-4L41C, 2-4M41(Z), 4L42C, 4M42
104
HATZ
Manual
Overview
2 Emergency start lever
3 Seal wire
Procedure
Step Activity
1 Check the oil level (see chapter 7.9 Check the oil level, page
57).
2 Remove the capsule hood or side trim panel (see chapter 5
Engine design, page 27)
3 Place a suitable tool, such as a screwdriver, behind the emer-
gency start lever(2) and tear the seal wire(3) between the
emergency start lever and the housing screw with a forceful
jerk.
4 Turn the emergency start lever to the start position.
5 Start the engine (see chapter 7.5 Starting the engine, page
41).
6 Eliminate the emergency situation within a few seconds.
7 Switch off the engine.
8 Immediately after the emergency operation phase:
Determine and remedy the cause of the fault signal (see
chapter 9.1 Trouble shooting, page 97).
If necessary, contact your nearest HATZ service station.