18
8 Maintenance
⚠ WARNING
Danger to life from mains voltage 230 V / 50 Hz
Electric shock
Always disconnect the device from the power supply before commencing
maintenance work.
Only qualied specialist personnel are permied to carry out maintenance
work on electric components.
⚠ CAUTION
Danger of crushing by rotang parts
Injuries to ngers and hands
Disconnect the device from the power supply.
Do not start up the device without the guard and housing parts.
iComponent-specic grease must be used for maintenance. For suitable grease, see
chapter 12 “Accessories” on page 31.
Disconnecng the power supply
Switch o the device.
Unplug the mains plug.
Lubricang the tappet at the lng head
iCheck every 4 weeks whether the tappet is sll fully lubricated with food-safe lu-
bricant.
iFor idencaon of the parts, see Tab. 3 on page 8.
Li the protecve cover
2
up.
Retain the lng head
1
at the locking clip
8
, pull the locking clip out to the stop
and guide the lng head upwards.
Where necessary, brush the tappet
6
generously with a suitable lubricant.
Maintenance