9 Troubleshoong
Fault Cause Soluon Illustraon
The device runs
with the protecve
cover open
The limit switch is
defecve
Switch
the device o.
Inform
customer
support
immediately.
The device doesn't
turn on
The protecve
cover is open
Close
the protecve
co ver.
The power supply
is interrupted
Insert
the mains plug.
Check
the fuses on
the installaon
side.
The lng head
is not clicking in
properly
Close the lng
head fully
and push
the locking clip
into the stop.
The limit switch
for the protecve
cover is not
correctly set
Set the limit
switch properly.
The device is run-
ning loudly
The drive chains
are too dry
Lubricate
the drive
chains, see
chapter 8
“Maintenance”
on page 18.
The upper coupling
is dry
Lubricate
the coupling.
The ball bearings
have worn out
Inform
customer
support.