Summary

Description

Whats Included

Professional Grade ORP Probe

Samples pool water, indicates oxidation-reduction potential (redox) for sanitizer activity and water quality.

Professional Grade pH Probe

Samples pool water, indicates acidity. Balances pool water pH when used with a dispensing device.

Probe Cell

Houses probes, provides water collection/testing location. Connects to filtration system supply/return.

Additional Pro Logic Relay

For Pro Logic PL-PS-4/PL-P-4 models with software <4.00 to add pH control.

pH Dispense Pigtails

Plug-in receptacle for pH dispensing devices like peristaltic pumps or solenoid valves.

Various Hardware

Includes necessary tubing, tubing connectors, and mounting hardware for installation.

Limited Warranty Information

Compatibility

Installation Overview

Mounting the Probe Cell

Details steps for mounting the Probe Cell, a key component for water sampling.

Plumbing the Probe Cell

Explains how to connect the Probe Cell to the pool plumbing for water flow.

Installing ORP and pH Probes

Guide for inserting the ORP and pH probes into the Probe Cell.

Wiring Probes to Probe Cell

Instructions for connecting the ORP and pH probe cables to the Probe Cell's communication box.

Wiring Probe Cell to Control Unit

Details how to connect the Probe Cell cable to the Aqua Rite Pro or Pro Logic controller.

Wiring pH Dispense Pigtail

Instructions for wiring the pH dispensing pigtail to the control unit.

Configuring the Controller

Steps to configure the Aqua Rite Pro or Pro Logic for the AQL-CHEM sensing kit.

Validating Operation

How to confirm that the installed system is functioning correctly.

Establishing Maintenance Schedule

Guidance on setting up a routine maintenance plan for the system.

Installation Materials

Side Mounting on Aqua Rite Pro

Side Mounting on Pro Logic

Winterizing the AQL-CHEM

Normal Operation

Maintenance

Water Chemistry Maintenance

Guidance on maintaining proper pool water chemistry for system accuracy.

Probe Maintenance

Instructions on cleaning and caring for the ORP and pH probes to ensure functionality.

Probe Storage

Procedures for storing probes correctly when they are removed from the Probe Cell.

Plumbing the Probe Cell

Plumbing Connections

Installing ORP and pH Probes

Controlling pH

Operation

Controlling ORP

Steps to set the desired ORP level for optimal pool water sanitization.

Wiring Probes to Probe Cell

Wiring Probe Cell to Controller

Wiring Pigtail;Dispensing Device

pH Calibration Wizard

Configuring pH Dispense Relay

Controller Settings

Chlorine Feed

Selects chlorine generation method: ORP Auto Sensing or Timed.

Maintain pH Level

Sets the target pH level for automatic dispensing of pH reducer.

pH Alarms

Configures high and low alarms for the pool's pH level.

pH Feed Timeout

Sets a timeout to prevent continuous pH reducer dispensing due to errors.

Maintain ORP Level

Sets the desired ORP level for automatic chlorine generation.

ORP Alarms

Configures high and low alarms for the pool's ORP level.

Chemistry Extend (Pro Logic only)

Keeps the filter pump running until sanitizer and pH levels are met.

Sanitizer Feed Timeout

Shuts down ORP control if it runs continuously due to probe errors.

Pro Logic Wiring

Configuring the Aqua Rite Pro or Pro Logic

Chemistry Config Wizard

Guides the user through automatic configuration of the AQL-CHEM sensing kit.

Sensing System

Enables the AQL-CHEM sensing system.

pH Reduction Control

Sets pH control mode: Disabled, Auto Sensing, or Forced On.

Summary

Description

Whats Included

Professional Grade ORP Probe

Samples pool water, indicates oxidation-reduction potential (redox) for sanitizer activity and water quality.

Professional Grade pH Probe

Samples pool water, indicates acidity. Balances pool water pH when used with a dispensing device.

Probe Cell

Houses probes, provides water collection/testing location. Connects to filtration system supply/return.

Additional Pro Logic Relay

For Pro Logic PL-PS-4/PL-P-4 models with software <4.00 to add pH control.

pH Dispense Pigtails

Plug-in receptacle for pH dispensing devices like peristaltic pumps or solenoid valves.

Various Hardware

Includes necessary tubing, tubing connectors, and mounting hardware for installation.

Limited Warranty Information

Compatibility

Installation Overview

Mounting the Probe Cell

Details steps for mounting the Probe Cell, a key component for water sampling.

Plumbing the Probe Cell

Explains how to connect the Probe Cell to the pool plumbing for water flow.

Installing ORP and pH Probes

Guide for inserting the ORP and pH probes into the Probe Cell.

Wiring Probes to Probe Cell

Instructions for connecting the ORP and pH probe cables to the Probe Cell's communication box.

Wiring Probe Cell to Control Unit

Details how to connect the Probe Cell cable to the Aqua Rite Pro or Pro Logic controller.

Wiring pH Dispense Pigtail

Instructions for wiring the pH dispensing pigtail to the control unit.

Configuring the Controller

Steps to configure the Aqua Rite Pro or Pro Logic for the AQL-CHEM sensing kit.

Validating Operation

How to confirm that the installed system is functioning correctly.

Establishing Maintenance Schedule

Guidance on setting up a routine maintenance plan for the system.

Installation Materials

Side Mounting on Aqua Rite Pro

Side Mounting on Pro Logic

Winterizing the AQL-CHEM

Normal Operation

Maintenance

Water Chemistry Maintenance

Guidance on maintaining proper pool water chemistry for system accuracy.

Probe Maintenance

Instructions on cleaning and caring for the ORP and pH probes to ensure functionality.

Probe Storage

Procedures for storing probes correctly when they are removed from the Probe Cell.

Plumbing the Probe Cell

Plumbing Connections

Installing ORP and pH Probes

Controlling pH

Operation

Controlling ORP

Steps to set the desired ORP level for optimal pool water sanitization.

Wiring Probes to Probe Cell

Wiring Probe Cell to Controller

Wiring Pigtail;Dispensing Device

pH Calibration Wizard

Configuring pH Dispense Relay

Controller Settings

Chlorine Feed

Selects chlorine generation method: ORP Auto Sensing or Timed.

Maintain pH Level

Sets the target pH level for automatic dispensing of pH reducer.

pH Alarms

Configures high and low alarms for the pool's pH level.

pH Feed Timeout

Sets a timeout to prevent continuous pH reducer dispensing due to errors.

Maintain ORP Level

Sets the desired ORP level for automatic chlorine generation.

ORP Alarms

Configures high and low alarms for the pool's ORP level.

Chemistry Extend (Pro Logic only)

Keeps the filter pump running until sanitizer and pH levels are met.

Sanitizer Feed Timeout

Shuts down ORP control if it runs continuously due to probe errors.

Pro Logic Wiring

Configuring the Aqua Rite Pro or Pro Logic

Chemistry Config Wizard

Guides the user through automatic configuration of the AQL-CHEM sensing kit.

Sensing System

Enables the AQL-CHEM sensing system.

pH Reduction Control

Sets pH control mode: Disabled, Auto Sensing, or Forced On.

Hayward AQL-CHEM Specifications