ISC850-99
MODELS C850, C1250
The ASL models C850
and C1250 are high
performance swimming
pool filters with a
maximum flow rating
of 70 gallons per hour.
Manufactured from
Hayward’s exclusive
PermaglassXL
material,
ASL is designed to
provide years of
trouble-free operation.
C. PLUMBING
Use 1-1/4” or 1-1/2” I.D. flexible plastic pipe or hose joined
with insert fittings and stainless steel clamps. If rigid PVC is
used, be sure to provide unions for easy servicing.
All plumbing connections on the ASL filter are 1-1/2” N.P.T.
When making connections, use plastic male-end adapters.
Apply three turns of Teflon tape or plastic pipe sealant to the
male threads. Screw the fitting into the thread hand tight;
then using a wrench, tighten one more full turn if necessary.
Adapters have varying tolerances and over tightening with a
wrench may only cause damage to the filter.
Ball type valves are recommended where needed. (See fig. 1)
Connect the pool suction plumbing between the skimmer,
pool outlet, and the pump.
Connect the pool return (inlet) plumbing.
A filter drain valve or plug is furnished with each filter and is
all that is needed for complete filter draining. A manual air
vent valve is furnished to aid in the bleeding of unwanted air
when starting or draining the filter.
All electrical connections should be made in accordance with
local codes.
Refer to pump instruction book for pump information.
.
NOTE: ANSI/NSPI-4 Article V, standard for above-ground and on-ground
pools, advises that components such as the filtration system, pumps and
heater be positioned so as to prevent their being used as a means of
access to the pool by young children.
A. FEATURES
New glass reinforced, non-corrosive Permaglass XL
filter
tank will provide years of trouble-free operation.
Easy-Lok
ring design allows quick access to all internal
components.
Unique safety latch prevents unwanted entry into the tank.
Self-venting design automatically purges any air present in
the system.
B. FILTER LOCATION
Though the filter is designed for outdoor use, it is advisable
to protect electrical components from the weather. Select a
well drained area, one that will not flood when it rains.
Set the filter on firm, level ground. Position the tank for
easy access to the internals, and pressure gauge, with at
least 24” (61 cm) for the C850 or 27” (69 cm) for the C1250
of top clearance. Position the filter so that it may drain by
gravity.
1.
2.
3.
4.
5.
6.
7.
8.
1.
2.
*
*Not furnished with filter.
*
Question and Answer IconNeed help?

Do you have a question about the Hayward ASL C1250 and is the answer not in the manual?

Hayward ASL C1250 Specifications

General IconGeneral
BrandHayward
ModelASL C1250
CategoryLighting Equipment
LanguageEnglish

Summary

Filter Features

Filter Location

Outdoor Use and Drainage

Protect electrical components from weather and select a well-drained area that will not flood.

Placement and Clearance

Set on firm, level ground with adequate clearance for access and gravity drainage.

Plumbing Connections

Pipe and Fitting Requirements

Use 1-1/4" or 1-1/2" I.D. flexible plastic pipe or hose with insert fittings and stainless steel clamps.

NPT Connections and Sealant

Use 1-1/2″ N.P.T. connections with plastic male-end adapters and Teflon tape or sealant.

Valve Recommendations

Ball type valves are recommended for plumbing connections.

Suction and Return Plumbing

Connect pool suction plumbing to skimmer/outlet and pool return (inlet) plumbing.

Electrical Connections

All electrical connections should be made in accordance with local codes.

Parts List and Specifications

Before Starting the Filter

Starting the Filter

Filtering Operation

Cartridge Cleaning and Replacement

Cleaning Cartridge Element

Open air relief valve, close valves, shut off pump, open drain and suction valves to flush.

Removing Cartridge Element

Depress safety latch, unscrew lid counterclockwise, and lift out filter element.

Reinstalling Element

Place lid evenly on body, turn clockwise until latch engages securely to safety latch.

Preventative Maintenance

Cartridge Cleaning Methods

Pressure wash cartridge, soak in cleaner for oils, or soak in muriatic acid for mineral deposits.

Vacuuming Procedure

Vacuum directly into filter. Clean filter before and after vacuuming for best results.

Winterizing the Filter

Drain or remove filter from location and store indoors in sub-freezing temperatures.

Service and Repairs

Algae Control and Pool Chemistry

Algae Growth Prevention

Maintain a free chlorine level of at least 1.0 ppm to prevent algae growth.

Pool Chemistry Guidelines

Provides suggested pH, alkalinity, chlorine, bromine, and stabilizer levels.