Automation and Chlorination
Operation Manual
for models
PL-PS-4 PL-PS-8-V
PL-PS-8 PL-PS-16-V
PL-PS-16
Quarterly Monthly Weekly
Free Chlorine 1.0 - 3.0 ppm
pH 7.2 - 7.8
Raise desired output % to
increase, lower desired output %
to decrease -OR- increase or
decrease pump filtration time.
Too low - add soda ash.
Too high - add muriatic acid
Alkalinity 80 - 120 ppm
Salt 2700 - 3400 ppm Add salt as required to increase.
Add baking soda to increase.
Stabilizer 60 - 80 ppm Add cyanuric acid to increase.
Calcium 200 - 400 ppm Add calcium to increase.
Electrolytic Cell inspect & clean Refer to section in manual.
TEST IDEAL RANGE ADJUSTMENT REQUIRED
Drain and add water to decrease.
Add acid as required to decrease.
Pro Logic
092331D RevG
Copyright © 2010 Hayward
www.hayward.com
620 Division St.
Elizabeth, NJ 07207

Other manuals for Hayward Pro Logic®

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hayward Pro Logic® and is the answer not in the manual?

Hayward Pro Logic® Specifications

General IconGeneral
CategoryWater Filtration Systems
AutomationYes
Heater ControlYes
Pump ControlYes
Lighting ControlYes
Salt Level MonitoringYes
DisplayLCD
Communication ProtocolProprietary
Enclosure RatingNEMA 3R
pH ControlYes
ORP ControlYes
Remote ControlYes
WiFi ConnectivityOptional
Voltage120/240V
Number of Relays4 to 8
CompatibilityHayward