EasyManua.ls Logo

Hayward SP23520VSP - User Manual

Hayward SP23520VSP
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
IS23520VSP Rev-D
Hayward Pool Products
620 Division St, Elizabeth, NJ 07207
Phone: (908) 355-7995
www.hayward.com
MaxFlo VS
500
Owner’s Manual
Model SP23520VSP
MaxFlo VS 500 Variable Speed Pump
Hayward’s MaxFlo VS 500 variable speed pump delivers incredible energy savings via its advanced
hydraulic design combined with a totally enclosed, permanent magnet motor. MaxFlo VS 500 is easily
installed either as a programmable stand-alone pump or with a Hayward or third party controller and
features an easy-to-use digital control interface that can be mounted in four different positions on the
pump or removed and mounted on the wall for total user convenience.
Note: To prevent potential injury and to avoid unnecessary service calls, read this manual carefully and
completely. Unless otherwise stated, instructions in this manual apply to both pump models.
SAVE THIS INSTRUCTION MANUAL

Questions and Answers

  • D
    david49Aug 20, 2025
    How to reduce noise from my Hayward Swimming Pool Pump?
    • A
      Anthony JohnsonAug 20, 2025
      If your Hayward Swimming Pool Pump is noisy, try correcting the suction condition or throttling return lines, if practical. Ensure the pump is mounted on a level surface and securely fastened to the equipment pad. Clean the pump housing. Any seal leaks should be replaced immediately.
  • R
    Ruben TateAug 23, 2025
    How to fix low flow in my Hayward SP23520VSP Swimming Pool Pump?
    • J
      judith27Aug 23, 2025
      If your Hayward Swimming Pool Pump has low flow, a clogged or restricted strainer or suction line could be the cause. Correct the piping size for undersized pool piping. Check for a plugged or restricted discharge line of filter, or a valve partially closed. Backwash as per manufacturer’s instructions. Re-tighten the suction and discharge connections using PTFE tape. Inspect other plumbing connections, and tighten as required. A plugged, restricted, or damaged impeller may be the cause, so replace the impeller including a new seal assembly.
  • A
    astevensonAug 25, 2025
    How to troubleshoot a Hayward SP23520VSP Swimming Pool Pump motor that will not start?
    • J
      Jennifer CookAug 26, 2025
      If your Hayward Swimming Pool Pump motor will not start, ensure the terminal board connections match the wiring diagram on the pump data plate label and that the pump is wired for the available field supply voltage (230VAC). Inspect for any improper or loose wiring connections, open switches or relays, tripped circuit breakers, or blown fuses, and correct as necessary. Manually check the motor shaft rotation for free movement and absence of obstructions, resolving any issues found.
  • S
    Sherry AndrewsAug 28, 2025
    How to stop my Hayward Swimming Pool Pump from interfering with home automation equipment?
    • D
      Daniel NelsonAug 28, 2025
      If your Hayward Swimming Pool Pump is interfering with home automation or power line communication equipment, ensure the terminal board connections match the wiring diagram on the pump data plate label. Also, check for and correct any improper or loose wiring connections. Consider installing a noise filter (available from your home automation/power line communication equipment vendor) to prevent equipment interference.
  • W
    Wanda NealAug 30, 2025
    What causes a 'Check System DC voltage too high' error on my Hayward SP23520VSP Swimming Pool Pump?
    • J
      John MillerAug 31, 2025
      If the system DC voltage is too high on your Hayward Swimming Pool Pump, verify that the line voltage is within 10% (207-253 VAC) of the pump's rated voltage at the terminal block.
  • L
    Lisa WoodSep 2, 2025
    What causes a 'Check System DC voltage too low' error on my Hayward SP23520VSP?
    • L
      Lori GibsonSep 2, 2025
      If the system DC voltage is too low on your Hayward Swimming Pool Pump, verify that the line voltage is within 10% (207-253 VAC) of the pump's rated voltage at the terminal block. Also, verify that power supply connections are properly made at the circuit breaker as well as at the terminal block.
  • J
    Jose WatersSep 5, 2025
    What does 'Check System Drive is overheated' mean on my Hayward SP23520VSP Swimming Pool Pump?
    • S
      Shannon GardnerSep 5, 2025
      If you receive a 'Check System Drive is overheated' error on your Hayward Swimming Pool Pump, make sure the motor airflow path is free from obstructions. Also, check the ambient temperature and compare it against the motor nameplate (50°C/122°F).
  • C
    crawfordmichaelSep 8, 2025
    What does 'Check System Drive overload' mean on my Hayward SP23520VSP?
    • L
      Lori JohnsonSep 8, 2025
      If you receive a 'Check System Drive overload' error on your Hayward Swimming Pool Pump, check the impeller, diffuser, shaft seal, and motor for any issues or binding.
  • D
    Dawn WilliamsSep 12, 2025
    What does 'Check System Pump failed to start' mean on my Hayward SP23520VSP Swimming Pool Pump?
    • C
      Curtis HaleSep 12, 2025
      If you receive a 'Check System Pump failed to start' error on your Hayward Swimming Pool Pump, check the impeller, diffuser, shaft seal, and motor for any issues or binding.
  • D
    daniel22Sep 13, 2025
    How do I fix a 'Check System Communication failed' error on my Hayward SP23520VSP Swimming Pool Pump?
    • S
      Steven JonesSep 13, 2025
      To address a 'Check System Communication failed' error on your Hayward Swimming Pool Pump, verify the connections between the user interface and the motor/drive.

Summary

Important Safety Instructions

Energy Efficiency Overview

Installation and Wiring

Grounding and Electrical Wiring

Critical safety, grounding, bonding, and wiring instructions.

Wiring Diagrams

Input Power Wiring

Diagram for connecting the main power supply to the pump.

Startup & Operation

Starting;Priming the Pump

Step-by-step guide on how to properly prime and start the pump.

Maintenance

Storage; Winterization

Shaft Seal Change Instructions

Seal Installation and Reassembly

Detailed guide for installing new seal and reassembling components.

Troubleshooting

General Problems

Solutions for common issues like motor not starting or noisy operation.

Check System Messages

Explanation of system error codes and their troubleshooting.

Hayward SP23520VSP Specifications

General IconGeneral
ModelSP23520VSP
CategorySwimming Pool Pump
TypeVariable Speed
Horsepower2.7 THP
Voltage230V
Energy EfficiencyEnergy Star Certified
Warranty3 Years
Motor TypePermanent Magnet
ControlDigital
Wet End MaterialThermoplastic