27
Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 • 9/09
INSTALLED
HORIZONTALLY
H
1
H
2
V
1
1. Top Vent - Horizontal Termination - (continued)
Note: There MUST be a 25% re-
duction in total H when using ex
vent except when using the sim-
ple up and out installation (see
Figure 7.3).
Figure 7.5
Two Elbows
V
1
Minimum** H
1
+ H
2
Maximum
90 Elbow Only** 1/2 ft. 152 mm
1/2 ft.** 152 mm 1 ft. 305 mm
1-1/2 ft.** 457 mm 2 ft. 610 mm
2-1/2 ft.** 762 mm 4 ft. 1.2 m
3-1/2 ft. 1.1 m 6 ft. 1.8 m
4-1/2 ft. 1.4 m 14 ft. 4.3 m
H
1
+ H
2
MAX. =14 ft. (4.3 m)
V
1
+ H
1
+ H
2
MAX. = 40 ft. (12.2 m)
**See Warning Below.
Fire Risk.
When using SLP-HRC-SS and SLP-HRC-ZC-SS
termination caps on top vented replaces, a one
foot minimum vertical vent section is required
before installing rst elbow.
When using DVP-TB1 termination cap on top
vented replaces, a three foot minimum vertical
vent section is required before installing rst
elbow.
WARNING**
Note: Use SLP Series
components only.