Hearth & Home Technologies • DV3732SBI, DV3732SBIL • 2215-900 • 9/09
EXISTING CHIMNEY
HEARTH
FLOOR
EXISTING CHIMNEY
EXHAUST AIR
VENT PIPE
INLET AIR
VENT PIPE
To minimize cold air
drafts, seal with
non-combustible
insulation.
TERMINATION CAP
DIRECT VENT FIREPLACE
V
TERMINATION CAP
EXISTING CHIMNEY
EXISTING CHIMNEY
EXHAUST AIR
VENT PIPE
V
FLOOR
HEARTH
H
To minimize cold air
drafts, seal with
non-combustible
insulation.
DIRECT VENT FIREPLACE
INLET AIR
VENT PIPE
Figure 7.21
Connecting the DV-46DVA-GCL Adapter to Appliance
Top Vent
Remove top seal cap and insulation if equipped. See
Section 14, “Appliance Setup.”
SLP Collar: Install the DV-46DVA-GCL adapter to
the appliance starting collar with 3-1/2 in. self-tapping
screws. See Figure 7.21.
Rear Vent
Remove the rear seal cap and insulation if equipped.
Connect the DVP-2SL adapter to the vertically positioned
elbow. Follow installation instructions included with DVP-
2SL kit. Secure DV-46DVA-GCL adapter to DVP-2SL with
3-1/2 in. self-tapping screws. See Figure 7.21.
Connecting the LINK-DV30B to the DV-46DVA-GCL
adapter
Insert the two sections of exible vent pipe down the
existing chimney.
Attach one section of exible vent pipe to the exhaust
TOP VENT
REAR VENT
WARNING! Risk of Fire, Explosion or Asphyxiation!
Do NOT connect this gas appliance to a chimney ue
serving a separate solid fuel or gas burning appliance.
May impair safe operation of this appliance or other
appliances connected to the ue.
Vent this appliance directly outside.
Use separate vent system for this appliance.
NOTICE: To achieve optimum per-
formance of appliance, minimize or
avoid bends in exhaust vent pipe.
collar on top of the DV-46DVA-GCL adapter with three
self-tapping screws.
Attach one section of exible vent pipe to the inlet collar
on top of the DV-46DVA-GCL adapter with three self-
tapping screws.
To minimize cold air drafts, seal around the ex vents
at the damper inside the chimney with non-combustible
unfaced berglass or rock wool insulation.
The DV-46DVA-GCL adapter must be recessed into existing
masonry replace. This measurement is taken from the top
of the replace opening. See Table 1 and Figure 7.20.
VH
Minimum 10 ft. 3.05 m 0 ft. 0 mm
Maximum 40 ft. 12.2 m 2 ft. 610 mm
V
Minimum 10 ft. 3.05 m
Maximum 40 ft. 12.2 m
CAUTION! DO NOT use any ue restric-
tor when venting with the DV-46DVA-GCL
adapter and LINK-DV30B kit. This may re-
sult in poor ame appearance, sooting, pilot
malfunction, or overheating.