15
Installation (cont.)
Vent-Free Gas Fireplace User’s Manual
INSTALLING THE HHFAN100 BLOWER (OPTIONAL)
Disconnect heater from the gas supply before installing the fan
accessory. Contact a qualified service person to do this.
1. Remove the blower panel using a screwdriver (see Fig. 5).
3.
Fig. 5—Remove Blower Panel
Fig. 6—Attach Blower Duct
Fig. 4—Grounded
Three-Prong Receptacle
Fig. 7—Attaching Thermal Switch Bracket
Attach blower thermal switch bracket to blower panel
with two screws provided. Note the bracket attaches to
the upper set of holes (see Fig. 7).
2.
Attach blower duct to the rear panel of the heater using three
screws provided (see Fig. 6
).
WARNING
Electrical grounding instructions: This appliance is
equipped with a three-prong (grounding) plug for
your protection against shock hazard and should be plugged directly
into a properly grounded three-prong receptacle (See Fig. 4).
Use lower set of holes