Service manual
9 Electronic function
9.1 Electronic control working environment
Input voltage: 175~253V or 100~130V, depending on model
I
n
p
u
t
p
o
w
e
r
f
r
e
q
u
e
n
cy
:
60Hz
Ambient temperature: 19°F to 110°F(heat pump), 64°F to 110°F(cooling only)
Indoor fan normal working amp is less than 1A
Outdoor fan normal working amp is less than 1.5A
Four-way valve normal working amp is less than 1A
Swing motor: DC12V
Compressor: single-phase power supply. Its normal working amp is less than 15A
9.2 Symbols and their meaning
T1: Indoor ambient
temperature
T2: Indoor evaporator temperature
T3: Outdoor condenser temperature.
TS: Setting temperature through the remote controller
TE1: Anti-cold wind, from Fan Off to Breeze temperature
TE2: Anti-cold wind, from Breeze to Setting Fan Speed temperature
TE3: Anti-cold wind, from Setting Fan Speed to Breeze temperature
TE4: Anti-cold wind, from Breeze to Fan Off temperature
TE5: Evaporator low temperature protection entering temperature
TE6: Evaporator low temperature protection restoring temperature
TE7: Evaporator high temperature protection, compressor off temperature
TE8: Evaporator high temperature protection, fan off temperature
TE9: Evaporator high temperature protection, restoring temperature
TE10: Condenser high temperature protection, compressor off temperature.
TE11: Condenser high temperature protection, restoring temperature.
TE14: The indoor restoring temperature when the compressor is off on the heating mode.
TE16: The indoor evaporator temperature after the defrost action, fan on temperature.
TC1: Outdoor condenser sensor temperature for the defrost condition 1.
TC2: Condenser sensor temperature after defrost.
TC3: Outdoor condenser sensor temperature for the defrost condition 2.
Heat Controller, Inc. Jackson, MI 49203