Page
34
240 VAC
Wiring
Refer
to
Detail
18C
for
the
following
steps.
( ) Remove
the
insulation
from
a
1"
length of
hookup
wire.
( )
Connect
a
1"
bare
wire
from
lug 2 (S-2) to
lug 3
(S-l)
of
the
power
transformer.
Solder
transformer
lug 1
(S-l).
)
Solder
transformer
lug 4 (S-2).
240
VAC
WIRING
Detail
l8C
BACK
OF
REAR
PANEL
.~~~i-
.:.:::.~~
1. PULL SLACK
OUT
OF
CORD.
2.
CR
IMP STRAI N
RELI
Ef
ON
CORD
ABOUT
ONE
INCH
FROM
REAR
PANEL.
3.
COMPRESS STRAIN RELIEF
SO
THAT
IT WILL
PASS INTO
HOLE
IN
REAR
PANEL. LINE-UP
FLATS
ON
STRAIN RELIEF WITH STRAIGHT SIDES
Of
HOLE.
4. PULL LINE
CORD
ON
INSIDE
OF
INSTRUMENT
TO
EXPAND STRAIN RELIEF .
....
------Detail
180
-----
.....
NOTE: In
the
following
step,
if
you have
used
the
flat
3-lead
line
cord
supplied
with
this
kit,
install
strain
relief
#75-71.
If
you have
used
a
round
line
cord
(not
supplied
with
this
kit),
install
strain
relief
#75-30.
( )
Refer
to
Detail
18D and
install
the
line
cord
strain
relief
on
the
line
cord.
This
completes
the
wiring
of
your
Heathkit Sine-
Square
Audio
Generator.
Carefully
inspect
all
solder
joints
for
unsoldered
wires
or
loose
con-
nections.
Remove any
wire
clippings
or
solder
splashes
that
may
be
lodged in
the
Wiring. Then
proceed
to
the
Knob
Installation
section.