Section Header
Model: Slimline-RF
30
Optional Settings - Feature Table
Temperature Format
Switching Differential
Frost Mode
Frost Protection Temperature
Output Delay
UH8-RF or RF-Switch Receiver
Receiver Board Address
Zone Number
Underfloor Heating or
Radiator (UH8-RF Only)
Fail Safe
Up/Down Limit
Sensor Selection
Not Used
Preheat Setting
Rate of Change
5/2 Day or 7 Day Programming
Thermostat Mode
DESCRIPTIONFEATURE
00 = °C, 01 = °F (°C = Default)
01° - 03°C (01°C = Default)
00 = Disabled, 01 = Enabled (01 = Default)
07° - 17°C (12°C = Default)
00 - 15 Minutes (00 = Default)
00 = UH8-RF, 01 = RF-Switch (00 = Default)
UH8-RF = 01-99, RF-Switch = 01-32
UH8-RF - 01-08, RF-Switch = Not Used
Underfloor Heating = 00,
Radiator Zone = 01
00 Disabled, 01 Enabled (00 = Default)
00° - 10°C (00°C = Default)
00 = Built in Air, 01 = Remote Air
Not Used
00-03 hours (00 = default)
Minute to raise 1°C
00 = 5/2 day, 01 = 7 day (00 = default)
00 = Manual, 01 = Programmable,
02 = Programmable + Hot Water
SETTING
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17