Heatmiser Slimline-RF - Optional Settings Feature Table; Feature 01: Temperature Format (Table); Feature 02: Switching Differential (Table); Feature 03: Frost Mode (Table)

Heatmiser Slimline-RF
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Section Header
Model: Slimline-RF
30
Optional Settings - Feature Table
Temperature Format
Switching Differential
Frost Mode
Frost Protection Temperature
Output Delay
UH8-RF or RF-Switch Receiver
Receiver Board Address
Zone Number
Underfloor Heating or
Radiator (UH8-RF Only)
Fail Safe
Up/Down Limit
Sensor Selection
Not Used
Preheat Setting
Rate of Change
5/2 Day or 7 Day Programming
Thermostat Mode
DESCRIPTIONFEATURE
00 = °C, 01 = °F (°C = Default)
01° - 03°C (01°C = Default)
00 = Disabled, 01 = Enabled (01 = Default)
07° - 17°C (12°C = Default)
00 - 15 Minutes (00 = Default)
00 = UH8-RF, 01 = RF-Switch (00 = Default)
UH8-RF = 01-99, RF-Switch = 01-32
UH8-RF - 01-08, RF-Switch = Not Used
Underfloor Heating = 00,
Radiator Zone = 01
00 Disabled, 01 Enabled (00 = Default)
00° - 10°C (00°C = Default)
00 = Built in Air, 01 = Remote Air
Not Used
00-03 hours (00 = default)
Minute to raise 1°C
00 = 5/2 day, 01 = 7 day (00 = default)
00 = Manual, 01 = Programmable,
02 = Programmable + Hot Water
SETTING
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17