62
USB hub
If you need further USB ports or if the supply current is not
sufficient, a USB hub is required. The USB hub from HEIDENHAIN
offers four free USB 2.0 ports.
USB hub ID 582884-xx
Voltage supply: DC 24 V/max. 300 mA
Cover The USB hub can be installed in the operating panel in such a
way that two USB ports can be accessed from the outside. An
optionally available cover cap can be used to protect the ports
from contamination.
Cover ID 508921-xx
Software for data
transfer
We recommend using HEIDENHAIN software to transfer files
between the MANUALplus 620 and a PC.
TNCremoPlus
(accessory)
This PC software package helps the user to transfer data from
the PC to the control. The software transfers data blockwise with
block check characters (BCC).
Functions:
•
Data transfer (also blockwise)
•
Remote control (only serial)
•
File management and data backup of the control
•
Reading out the log
•
Print-out of screen contents
•
Text editor
•
Managing more than one machine
TNCremoPlus
(accessory)
In addition to the features you are already familiar with from
TNCremo,TNCremoPlus can also transfer the current content of
the control’s screen to the PC (live screen). This makes it very
simple to monitor the machine.
Additional functions:
•
Query of DNC data (NC up time, Machine up time, Machine
running time, Spindle running time, pending errors, data from
the data servers, e.g. symbolic PLC operands)
•
Targeted overwriting of tool tables (merge mode)
TNCremoPlus ID 340447-xx