EasyManua.ls Logo

HEIDENHAIN POSITIP 880 - Page 31

HEIDENHAIN POSITIP 880
151 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
POSITIP 880 31
I – 3 Actual Value
0 is offered as a default value for the coordinate. Enter
the desired coordinate for the workpiece edge, for
example Y = 0 mm and
set the coordinate as a datum for this workpiece
edge. Press ENT.
Press USE soft key.
Example: Set centerline between two workpiece edges as datum.
See Fig. I.23 & Fig. I.24.
The position of the centerline M is determined by probing the edges 1
and 2.
The centerline is parallel to the Y axis.
Desired coordinate of the centerline: X =0 mm
Operating mode: ACTUAL VALUE
Press PROBE.
Cursor to the axis for which the coordinate is to be
set: X axis.
Press CENTER LINE.
Move the edge finder toward workpiece edge 1 until
the LEDs in the edge finder light up.
Move the edge finder toward workpiece edge 2 until
the LEDs in the edge finder light up. The distance
between the edges is displayed on the message bar.
Retract the edge finder from the workpiece.
ENTER VALUE FOR Y + 0
Fig. I.23 Setting centerline between two edges
Fig. I.24
Spacing between edges is displayed on the message bar
when using the probe centerline feature.
1. PROBE 1ST EDGE IN X
2. PROBE 1ST EDGE IN X