I – 5 Milling Patterns
Enter the X and Y coordinates of the circle center
(both 50).
Press ENT.
Enter the radius of the circle pattern (20).
Press ENT.
Enter the start angle (30°).
Press ENT.
Enter the depth of each hole (-5.0).
Press ENT.
8 Press USE soft key to begin step.
8 Pressing the VIEW () soft key will toggle through the
different views of the pattern (Graphic, etc.).
CENTER
RADIUS
START ANGLE
DEPTH
When in TOOL field enter the TOOL TABLE and select the
desired tool.