8 Inputs and Outputs
ARIADNE Knock Control 21
8 Inputs and Outputs
On ARIADNE IP00 version, all inputs and outputs are wired on terminal strips.
On the IP55 version, all inputs and outputs are wired over plug-in connectors.
All inputs and outputs are reverse polarity proof and short circuit proof against battery posi-
tive and battery negative.
8.1 Power Supply
Operating voltage 24 V DC
Min. voltage 16 V DC
Max. voltage 36 V DC
Residual ripple max. 10 % with 100 Hz
Current consumption max. 1 A
External fuse protection 6 A
8.2 Inputs
Speed sensor input
Number of inputs 1
Frequency range f
i
= 25 .. 9000 Hz
Voltage range U
i
= 0.5 .. 30 V AC (inductive sensor)
U
i
= 12 V AC (hall sensor)
Phase sensor input
Number of inputs 1
Frequency range f
i
= 25 .. 9000 Hz
Voltage range U
i
= 0.5 .. 30 V AC (inductive sensor)
U
i
= 12 V AC (hall sensor)
Analog input
Number of inputs 1
used as voltage input U = 0 .. 5 V, R
e
= 100 k, f
g
= 15 Hz,
U
ref
= 5 V 25 mV, I
ref
< 20 mA
or
used as current input I = 4 .. 20 mA, R
e
= 200 , f
g
= 15 Hz,
U
ref
= 5 V 25 mV, I
ref
< 20 mA