EasyManua.ls Logo

Heinzmann ARIADNE - 8 Inputs and Outputs; Power Supply; Inputs

Heinzmann ARIADNE
37 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8 Inputs and Outputs
ARIADNE Knock Control 21
8 Inputs and Outputs
On ARIADNE IP00 version, all inputs and outputs are wired on terminal strips.
On the IP55 version, all inputs and outputs are wired over plug-in connectors.
All inputs and outputs are reverse polarity proof and short circuit proof against battery posi-
tive and battery negative.
8.1 Power Supply
Operating voltage 24 V DC
Min. voltage 16 V DC
Max. voltage 36 V DC
Residual ripple max. 10 % with 100 Hz
Current consumption max. 1 A
External fuse protection 6 A
8.2 Inputs
Speed sensor input
Number of inputs 1
Frequency range f
i
= 25 .. 9000 Hz
Voltage range U
i
= 0.5 .. 30 V AC (inductive sensor)
U
i
= 12 V AC (hall sensor)
Phase sensor input
Number of inputs 1
Frequency range f
i
= 25 .. 9000 Hz
Voltage range U
i
= 0.5 .. 30 V AC (inductive sensor)
U
i
= 12 V AC (hall sensor)
Analog input
Number of inputs 1
used as voltage input U = 0 .. 5 V, R
e
= 100 k, f
g
= 15 Hz,
U
ref
= 5 V 25 mV, I
ref
< 20 mA
or
used as current input I = 4 .. 20 mA, R
e
= 200 , f
g
= 15 Hz,
U
ref
= 5 V 25 mV, I
ref
< 20 mA

Related product manuals