7 Error Handling
Programmer PG 02 39
Cause: Oil pressure has fallen below the speed dependent oil pressure emergency
stop characteristic.
Response: - Emergency shutdown.
Action: - Check engine (oil level, oil pump, etc., ...).
- Check oil pressure sensor.
- Check cable of oil pressure sensor.
- Check oil pressure emergency stop characteristic
3032 ErrCoolantTempWarn 3132 SErrCoolantTempWarn
Cause: Coolant temperature has exceeded the warning threshold..
Response: - Error message.
- Error is cleared automatically when coolant temperature returns
below the warning characteristic.
Action: - Check coolant.
- Check coolant temperature sensor.
- Check cable to coolant temperature sensor.
- Check warning threshold.
3033 ErrChargeAirTempWarn 3133 SErrChargeAirTempWarn
Cause: Charge air temperature has exceeded the warning threshold.
Response: - Error message.
- Error is cleared automatically when charge air temperature is again
below the warning characteristic.
Action: - Check charge air.
- Check charge air temperature sensor.
- Check cable to charge air temperature sensor.
- Check warning threshold.