7 Error Handling
40 Programmer PG 02
3034 ErrOilTempWarn 3134 SErrOilTempWarn
Cause: Oil temperature has exceeded the warning threshold.
Response: - Error message.
- Error is cleared automatically when oil temperature is again
below the warning characteristic
Action: - Check oil.
- Check oil temperature sensor.
- Check cable to oil temperature sensor.
- Check warning threshold.
3044 ErrCoolantPressWarn 3144 SErrCoolantPressWarn
Cause: Coolant pressure has dropped below the speed dependent coolant pressure
warning characteristic.
Response: - Error message.
- Error is cleared automatically when coolant pressure is back above the
coolant pressure warning characteristic.
Action: - Check engine (coolant level, coolant pump, etc., ...).
- Check coolant pressure sensor.
- Check cable of coolant pressure sensor.
- Check coolant pressure warning characteristic
3045 ErrCoolantPressIdle 3145 SErrCoolantPressIdle
Cause: Coolant pressure has dropped below the speed dependent coolant pressure
forced idle speed characteristic.
Response: - Forced idle speed.
- Error message.
- Error is cleared automatically when coolant pressure is back above 10 %
of the coolant pressure forced idle speed characteristic.
Action: - Check engine (coolant level, coolant pump, etc., ...).
- Check coolant pressure sensor.
- Check cable of coolant pressure sensor.
- Check coolant pressure forced idle speed characteristic