2.15. Door switch
The door switch refers to the switch on the sauna door. This switch complies with regulations. Public and private saunas
must have a door switch, i.e. saunas where the heater can be switched on from outside the sauna, e.g. using an On/Off
button or a similar method.
The control panel automatically registers when the door switch is connected to the heater's OLEA 103 circuit board.
When using the sauna for the first time after the installation, close the door to the sauna room and turn on electricity
using the heater's main switch.
If the door is opened before the heating sequence is started, (pre-set heating) automatic use (remote use) is disabled
after one minute. The door must be closed and the function restarted from the control panel.
If the door has been left open for more than five minutes while the heater is on, the heater is automatically turned off.
The heater can be turned on again from the control panel after the door is closed. The fault indicator light, if installed, will
start flashing. See installation instructions below.
Door switch instructions for installation and connection
The door switch is installed outside the sauna room on the upper edge of the door, at least 300 mm from the inner
corner.
The switch part is installed on the door frame and the magnet is installed on the door. The distance between the switch
and the magnet is 18 mm.
When the door switch is installed on the top part of the door, Sauna360 recommends using the Sauna360 model with
product number 0043233, SSTL 8260371.
When the door switch is installed on the bottom part of the door, Sauna360 recommends using the Sauna360 model with
product number SP11000326, SSTL 8263280.
See the installation and user instructions supplied with the heater for instructions.
Figure 7 Installing the door switch
Figure 8 Pin - order of RJ 10
Table 4. Connecting the door switch.
Door switch
Conductor colour
Pin 1
Pin 2
Pin 3
Door switch
GND
Orange
Pin 4
Door switch
12 VDC
Green/white
Magnet on
the door
Max 18 mm
Door switch Min. 300 mm Junction box
Door switch
position when
installed on
lower part of the
door
3
4
Contactor box
OLEA 103
Connection
box
Connect the brown and
black door switch wires.
(closing contact)
Door switch
Magnet for the door
10