# Funkcja Description
7 key informs that all buttons are locked, in order to unlock the buttons simultaneously
press and hold for 5 seconds the up and down buttons. The keypad lock will be
automatically activated after 1 minute of inactivity;
8 settings change mode informs about controller settings change mode activated, in order to deactivate it
press button [10] (regeneration);
9 Enter entering settings change mode, settings change and confirmation
10 manual regeneration instant regeneration button, press in the service cycle to activate regeneration,
or move to another regeneration phase
11 down moving to next option
12 up moving to previous option
13 capital letter D (day) informs that the digital indication is in days
14 Symbol m^3 informs that the digital indication is in cubic meters (1 cubic metre = 1000 litres)
15 capital letter M informs that the digital indication is in minutes Colour strips are lit on the left
side of the display during water treatment. The number of current operation
cycle (description below) and the time remaining are displayed during
regeneration
16 capital letter L informs that the digital indication is in litres
17 capital letter H informs that the digital indication is in hours
18 gal informs that the digital indication is in gallons
8.2.2. FUNCTIONS OF BUTTONS IN PROGRAMMING MODA (230459 ONLY)
After the programming mode is entered into, the
following functions are assigned to buttons:
• Enter [9]: this button is used to activate and
confirm (after setting) the changed value. After
activation, the active value (currently changed)
blinks alongside the regulation symbol [8]. Now
this value can be changed. After the set value is
confirmed with enter [9], the regulation symbol
[8] will stop blinking, whereas the controller will
confirm the change with a short sound signal;
• Regeneration [10]: leaving the programming
mode or changing values and moving to the pre-
vious mode of the controller;
• Down [11] changing the type of parameter to be
programmed or reducing the active value;
• Up [12] changing the type of parameter to be
programmed or increasing the active value
NOTE: Operation cycles time 2-5 is always pre-programmed adequately to the type
and quantity of resin in the container and the size of brine tank. The quantity of
treated water was determined on the basis of the results of water examination de-
livered by You or average values. A potential correction of these parameters shall
be consulted with the delivered of the device.
In the event of a power supply failure, the controller is equipped with a feature to
store the programmed parameters (including the current time) for 7 days.