1
OPERATING AND INSTALLATION
INSTRUCTIONS
DANISH DESIGN . DANISH QUALITY . DANISH PRODUCTION
www.heta.dk
EN
AMBITION STOVE
is exemt for use in smoke control areas when burning dry wood.
Pending

Questions and Answers

  • P
    pmartinezAug 30, 2025
    What to do if vermiculite in Heta stove's combustion chamber is worn?
    • S
      Stanley HillAug 30, 2025
      If the vermiculite in your Heta stove's combustion chamber is becoming very worn due to wood and flue gases, keep in mind that normal wear and minor cracks are of no significance. It should be replaced when the steel of the combustion chamber is visible.
  • M
    Marc RamirezAug 29, 2025
    Why the steel surfaces in Heta stove combustion chamber have oxidised?
    • J
      John MooreAug 29, 2025
      If the steel surfaces in your Heta stove's combustion chamber have oxidised, it means the temperature in the combustion chamber is too high. If there are clear cracks or weaknesses in the stove body, it must be replaced.
  • G
    Gary SmithAug 28, 2025
    What to do about cracked vermiculite in Heta stove's combustion chamber?
    • R
      Richard DavisAug 28, 2025
      If the vermiculite in your Heta stove's combustion chamber is cracked due to shocks or impacts while adding firewood, note that these cracks only have cosmetic significance. Replacement is needed when the steel of the combustion chamber is visible.
  • R
    Rachel JoyceAug 27, 2025
    How to fix lighting problems with Heta stove when smoke seeps into the room?
    • E
      Edward BarronAug 27, 2025
      If you're experiencing lighting problems with your Heta stove, and smoke seeps into the room when the stove is cold, this indicates an inadequate chimney draft. To resolve this, improve the chimney.
  • Q
    qrodgersAug 27, 2025
    Why Heta Ambition 5 is whistling?
    • J
      Jeremy RogersAug 27, 2025
      If your Heta stove is whistling, it is likely due to too much chimney draft. To solve this, install a damper.
  • B
    benjamin99Aug 25, 2025
    What to do if Heta stove has too rapid combustion?
    • S
      Shelia SmithAug 26, 2025
      If your Heta stove experiences too rapid combustion, it could be due to too much chimney draft. Measure the chimney draft and install a damper in the flue pipe if necessary. Another potential cause is a defective door or ash pan/drawer seal, in which case you should replace the seal.
  • C
    Casey DavisAug 25, 2025
    Why Heta Ambition 5 Stove burns poorly after warm-up and the glass slowly soots up?
    • E
      Eric LawrenceAug 25, 2025
      If your Heta stove burns poorly after the warm-up phase and the glass slowly soots up, it may be due to soot in the flue pipe. To resolve this, clean regularly, limit the use of horizontal flue pipes, and avoid using firewood that generates large quantities of ash.

Summary

Before Installation

Unpacking the stove

Instructions for safely unpacking the wood stove and disposing of packaging materials.

Operating Instructions

1.1 Before using

Checks and considerations before operating the wood stove for the first time.

1.2 First firing

Guidance on the initial firing process to cure the stove’s heat-resistant coating.

1.3 Regulating the air flow

Explanation of how to control the stove’s combustion air using the handle.

1.4 Lighting the stove

Step-by-step instructions for safely lighting the wood stove.

1.5 Refueling

Guidance on how and when to refuel the stove with wood.

1.6 Emptying the ash

Instructions on how to safely empty ash from the combustion chamber.

1.7 Reduced burning

Advice on how to adjust burning for lower heat output and potential issues.

1.8 Explosion Hazard

Warning and explanation of potential explosion hazards and necessary precautions.

1.9 Draft conditions and the chimney

Explanation of chimney draft, its importance, and factors affecting it.

1.10 Fuel

Guidelines on the types of fuel to use and avoid for optimal performance and safety.

1.11 Operational problems

Information on common operational issues and how to address them.

1.12 Chimney fire

Procedures to follow in case of a chimney fire and subsequent inspection.

1.13 Maintenance

General guidance on cleaning and maintaining the stove’s exterior.

1.14 Cleaning the glass

Methods for cleaning soot from the stove’s viewing glass.

1.15 Troubleshooting table

A comprehensive table listing faults, causes, troubleshooting steps, and solutions.

1.16 Diagram for the maintenance

A schedule outlining maintenance tasks for stove owners and qualified technicians.

1.17 Cleaning after sweeping

Instructions for cleaning fire bricks and related areas after chimney sweeping.

1.18 Stove data table

A table detailing technical specifications and test results according to EN 13240.

1.19 Guarantee

Information regarding the stove’s warranty period and what it covers and excludes.

1.20 Parts - Doors

An illustrated list of parts related to the stove’s doors and their quantities.

Installation Instructions

2.1 Distance Provisions

Specifies minimum safe distances to combustible and non-combustible materials.

2.2 Floor

Requirements for the floor substrate supporting the stove and chimney.

2.3 The chimney connection

Guidelines for connecting the stove to various types of chimneys, ensuring compliance.

2.4 Combustion air and Ventilation

Details on providing adequate combustion air and room ventilation for efficient operation.

2.5 Stovedrawings;measurments

Technical drawings and dimensions for the Ambition stoves.

2.6 Connecting direct air - behind

Instructions for connecting an external air supply to the stove via the rear intake.

2.7 Clearances for installation

Detailed clearances required for installation according to EN 13 240 standard.

Data Plate and Regulations

3. Data plate

Information found on the product’s data plate for identification and specifications.

Appendix A - Clean Air Act and Smoke Control Areas

Explanation of smoke control areas and the stove's suitability for them.

Heta Ambition 5 Specifications

General IconGeneral
CategoryStove
Fuel TypeWood
Flue Outlet Diameter150 mm
Max. log length30 cm
MaterialSteel

Related product manuals