4
Declaration of Performance EN
_____________________________________________________________________________
_________________________________________________________________________________________
In case of any change of the above-mentioned production type this Declaration of Performance becomes invalid.
Heta A/S, Jupitervej 22, DK - 7620 Lemvig, Tlf.: +45 96630600, www.heta.dk
Page 1 of 1
Re
gulation No. 305/2011
DOP-Inspire 55-55H-3900-2016-EN
1. Unique identification code of product-type
Wood stoves
2. Product name
Inspire 55 – Inspire 55H
3. Intended use or uses of the construction
produc
t, in accordance with the applicable
technical specification
Room heater burning solid fuel without hot water supply
4. Name and contact address of the
manufacturer
Heta A/S; Jupitervej 22
DK – 7620 Lemvig; heta@heta.dk
5. Where applicable, name and E-mail address
of authorized representative
6. System of assessment and verification of
constancy of performance of the construction
product
System 3
7. Notified body relevant to the assessment and
verification of constancy of performance
RRF Rhein -Ruhr feuerstätten Prüfstelle GmbH. 46047 Oberhausen,
Deutschland
Notified body No. NB 1625
8. De
clared Performance:
Harmonized technical specification
EN 13240:2001/AC:2006
Emission CO: 0,1%
Nox: 130 mg/Nm³
Dust 28 mg/N
Dust(NS3058/3059) 1,97 g/kg
OGS (CEN/TS 15883) 100 mgC/Nm³ ved 13% O2
9. F
ire safety :
Reaction to fire A1
Test of fire safety in connection with the burning of
wood.
Approved
Distance to combustible materials
Rear:
Sides distance to combustible materials
Distance to floor from lower edge of the door
Furniture Distance:
Minimum distances i mm
150/220 mm
420 mm
430 mm
1200 mm
1
0. safety :
Mechanical resistance (to carry a chimney / flue) Not tested (NPD)
Electrical safety NA
Surface temperature Approved
Cleanability No specification
1
1. Thermal output :
Nominal heat output 6 kW
Energy efficiency
80 %
Fluegas temperature at nominal heat output T 263 °C
Water heating output NA
Maximum water operating pressure
NA
The performance of the product identified in points1 and 2 is in conformity with the declared performance in point 8. This
declaration of performance is issued under the sole responsibility of the manufacturer.
S
igned on behalf the manufacturer of:
____________________________________
Lemvig 18-08-2016. Lars Kirk HOD