HETRONIC SYSTEM COMPONENTS
The Hetronic radio remote control system consists of a
receiver and transmitter with belt, battery charger, and
two rechargeable batteries.
Nova-M Dig-V04 Transmitter Standard Features
Removable key power switch
E-stop switch
1 1-detent momentary start/horn pushbutton
1 1-detent momentary option pushbutton
2 dual axis 2-detent joysticks
1 three position toggle (check accompanying
documentation for exact toggle type)
•Sleep mode
100 m (300 ft.) range
Internal antenna
Waist belt
Nova-M Dig-V05 Transmitter Standard Features
Removable key power switch
E-stop switch
1 1-detent momentary start/horn pushbutton
1 1-detent momentary option pushbutton
1 dual axis 3-detent joystick
1 single axis 3-detent joystick
1 three position toggle (check accompanying
documentation for exact toggle type)
•Sleep mode
100 m (300 ft.) range
Internal antenna
Waist belt
RX 14 Receiver Standard Features
Start relay, horn relay, E-Stop relay
Up to 14 digital outputs
Self-diagnostics
48 V, 115 V or 230 V supply power for AC
cranes/machines
12VDC or 24VDC supply power for DC
cranes/machines
RX 20-0020 Receiver Standard Features
Start relay, horn relay, E-Stop relay, and two option
relays
Up to 20 digital outputs
Self-diagnostics
48 V, 115 V or 230 V supply power for AC
cranes/machines
12VDC or 24VDC supply power for DC
cranes/machines
RX 20-0021 Receiver Standard Features
Start relay, horn relay, E-Stop relay, and two option
relays
Up to 20 digital outputs
Self-diagnostics
48 V, 115 V or 230 V for AC cranes/machines
12VDC or 24VDC for DC cranes/machines
SYSTEM OVERVIEW
Theory of Operation
The Hetronic radio remote control system includes a
transmitter and a receiver. These systems operate over
the 400-470 MHz radio band range (70 cm band) and
are FCC approved.
The transmitter generates the electronic signal that
communicates with the receiver. The transmitter and
receiver are set with identical address codes and
frequency channels. This allows operation of multiple
systems within the same area without signal
interference.
The receiver only accepts commands from the
transmitter with the same address code.
NOTE: The receiver and transmitter have the address
code set at the factory.
E-Stop Function
The most important feature of the radio remote control
system is the E-Stop. The transmitter sends the E-stop
status signal along with the specified crane/machine
function. This method confirms that ongoing operations
are safe. If the E-stop pushbutton is pressed, the E-stop
relay in the receiver causes all crane/machine motions
to stop. The receiver goes into Safe mode.
To restart the system, disengage the E-stop button and
press the Start button.
The E-Stop responds faster than any other function.
When E-Stop is engaged, the system ignores any other
signal that is transmitted. The problem must be
corrected before the system will respond to any other
signal.
The E-Stop is self-monitoring and redundant in the
transmitter and receiver. The system performs a
self-test to ensure the E-Stop circuit is working properly.
If an error is detected, the system automatically goes
into Safe mode.
When the transmitter is turned on, it performs a self-test
to be sure that communications are within designated
parameters. If an error is detected, the transmitter will
not transmit any signals.
Transmitter Sleep Mode
The transmitter sleep mode is designed to prevent
accidental operation. The sleep mode can be set for 10
minutes. If the transmitter is not used for the sleep mode
period, it turns itself off. The controls are not operational
while the transmitter is in sleep mode. To restart the
transmitter, turn the key switch off and then back on, and
press the Start/horn button.
IMPORTANT: If the transmitter has a maintained toggle
switch that is engaged, sleep mode will not occur.