Do you have a question about the Hewalex G-422-P09 and is the answer not in the manual?
Data logging | No |
---|---|
Communication interface | No |
Display | LCD |
Power supply | 230 VAC |
Pump control | Yes |
Frost protection | Yes |
Overheat protection | Yes |
Application | Solar water heating systems |
Operating temperature | 0-50 °C |
Details the controller's physical dimensions and highlights its user-friendly design and features.
Explains the controller's various inputs and outputs, including connections for sensors, pumps, and external devices.
Guides the user through the first power-on, calibration process, and basic operation modes.
Explains how to select the appropriate installation scheme for the controller's correct operation.
Details scheme 1 for tap water heating, focusing on controlling the solar collector pump.
Describes scheme 2 for tap water heating, controlling both collector and circulation pumps.
Outlines scheme 3 for tap water heating, incorporating collector, circulation pumps, and a boiler.
Details scheme 4 for tap water heating with collector pump, circulation pump, and electric heater.
Explains scheme 5 for tap water heating with collector pump, circulation pump, and heat pump.
Covers scheme 6 for tap water heating with circulation pump and fireplace/solid-fuel boiler pump.
Details scheme 7 for a double heater system using a mixing pump for additional solar energy.
Explains scheme 8 for a double heater system using a circulation return for solar energy.
Describes scheme 9 for tap and pool water heating using a three-way valve and pool pump control.
Outlines scheme 10 for tap and pool water heating with an additional pump and pool pump control.
Details scheme 11 for a double heater system with a three-way valve and circulation pump control.
Explains scheme 12 for a double heater system with an additional pump and circulation pump control.
Covers scheme 13 for a buffer tank system cooperating with central heating installation.
Details scheme 14 for combi heater with solar, electric/liquid-fuel boiler, and solid-fuel boiler.
Explains scheme 15 for tap water heating, controlling solar collector pumps in various directions.
Covers scheme 16 for a double heater system with a three-way valve and solar collector pumps.
Details scheme 17 for tap water heating with collector pump, circulation pump, and heater cooling system.
Explains scheme 18 for tap water heating with solar, boiler heating, and fireplace/solid-fuel boiler pump control.
Covers scheme 19 for tap water heating with solar collector pump, mixing pump, and boiler heating via circulation return.
Covers setting control parameters and configuring time programs for various devices.
Details parameters for heat transfer fluid, flow rate, and collector pump speed settings.
Explains how to restore default settings and details various operational parameters.
Covers settings for date, time, display, sounds, language, and RS485 port.
Enables manually switching all devices in a given installation scheme on or off.
Explains the function for cooling tap water heater by switching solar collector pumps on.
Covers collecting energy data, thermal energy reports, and tracking anode operation time.
Details the vacation mode and the procedure for updating controller software.
Provides detailed descriptions of various control parameters for system configuration.
Lists and explains error alarms related to sensors, flow, pressure, and system faults.
Provides information on the proper disposal and collection of used electronic equipment.