User manual for G3
29
Management token
Any of the following Management tokens may be submitted:
Setting the maximum power.
Clearing the credit balance.
Changing the meter key.
In terms of the STS standard the meter requires 2 token codes to change the
key. There is no sequence between two tokens but the user must enter the
second token within 2 minutes after entering the first token otherwise the first
token entered will be disregarded.
Clear event status.
Prepayment mode to postpaid mode.
postpaid mode to Prepayment mode
Test token
Test Token
Full test
5649-3153-7254-5031-3471
Relay test
0000-0000-0001-5099-7584
LCD test
0000-0000-0001-6777-4880
Display import active energy.
0000-0000-0002-0132-8896
Display the key version.
1844-6744-0738-4377-2416
Display tariff index
3689-3488-1475-5332-2496
Display maximum power.
0000-0000-0012-0797-4400
Display meter status.
0000-0000-0022-8172-8512
Display power
0000-0000-0044-2920-8064
Display meter version
0000-0000-0087-2419-5840
Display three-phase imbalance level
0000-0000-0173-1410-5857