2.11 Status LEDs
2.11.1 Power-up
LED 1 turns ON, then LEDs 2 through 7 are turned ON then OFF in sequence.
2.11.2 Running
LED Description
1 On-line, encryption disabled = 0.8 second ON, 0.2 second OFF
On-line, encryption enabled = 0.1 second ON, 0.1 second OFF, 0.1 second ON, 0.1 second OFF0.1 second ON, 0.1
second OFF0.1 second ON, 0.3 second OFF
Off-line: 0.2 second ON, 0.8 second OFF
Waiting for application firmware to be downloaded: .1 sec ON, .1 sec OFF
2 Input IN1 Status: OFF = Inactive, ON = Active, Flashing = Fault
1
3 Input IN2 Status: OFF = Inactive, ON = Active, Flashing = Fault
1
4 Input IN3 Status: OFF = Inactive, ON = Active, Flashing = Fault
1
5 Input IN4 Status: OFF = Inactive, ON = Active, Flashing = Fault
1
6 Input IN5 Status: OFF = Inactive, ON = Active, Flashing = Fault
1
7 Input IN6 Status: OFF = Inactive, ON = Active, Flashing = Fault
1
J1-Yellow Ethernet speed: OFF = 10 Mb/S, ON = 100 Mb/S
J1-Green
OFF = No link, ON = Good link, Flashing = Ethernet activity
1. If this input is defined, every three seconds the LED is pulsed to its opposite state for 0.1 second, otherwise, the LED is off.
2.12 IT security
Ensure that the is installed securely. Create user accounts to the web configuration page using secure passwords.
Ensure all DIP switches are to be in the OFF position for the normal operating mode.
The is shipped from the factory with a default login account, which is enabled when DIP 1 is moved from OFF to ON (See
2.3 DIP switches). The default login user name (admin) and password (password) will be available for five minutes once
the DIP switch is toggled. It is therefore important that at least one user account is defined, and the DIP switches are set
to OFF before the is commissioned.
Configuring the with an IP address that is accessible from the public is not recommended.
The following options are available for enhanced network security:
l
Disable SNMP.
l
Zeroconf discovery.
l
The web configuration module.
l
Enable data encryption over the host communication port.
PLT-05249, A.1 12 August 2022
Powering
Trusted Identities
HID®Mercury™ MR62e OSDP Reader Interface
Installation and Specifications

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HID Mercury MR62e and is the answer not in the manual?

HID Mercury MR62e Specifications

General IconGeneral
BrandHID
ModelMercury MR62e
CategoryCard Reader
LanguageEnglish

Related product manuals