40
Note
Standard DC-09 Protocol
ADM-CID: The data presenting method of DC-09 is CID, which is not encrypted and only for
uploading alarm report.
*ADM-CID: The data presenting method of DC-09 is CID, which is encrypted and only for
uploading alarm report.
SIA-DCS: The data presenting method of DC-09 is DCS (also called SIA protocol), which is not
encrypted and only for uploading alarm report.
*SIA-DCS: The data presenting method of DC-09 is DCS (also called SIA protocol), which is
encrypted and only for uploading alarm report.
ADM-CID or SIA-DCS: You should select the Address Type as IP or Domain name, and enter the
Server address, port number, account code, impulse counting time, attempts, polling rate, etc.
Note
Set the polling rate with the range from 10 to 3888000 seconds.
ISUP, CSV-IP: You do not need to set the protocol parameters.
*SIA-DCS or *ADM-CID You should select the Address Type as IP or Domain name, and enter
the IP address, port number, account code, impulse counting time, attempts, polling rate,
encryption arithmetic, password length, etc.
Note
Set the polling rate with the range from 10 to 3888000 seconds.
ADM-CID, SIA-DCS, *SIA-DCS, *ADM-CID, CSV-IP: You can enable Intruder Verification as a
Service.
Note
When enabled, the SDK returns the URL address of the video storage after the PIRCAM
composite video is uploaded to the cloud. The control panel will add this URL in the additional
field when reporting the intruder verification to ARC. After receiving the URL, ARC can download
the video.
The alarm video can be stored in the cloud for up to 7 days.
4. Select the connection type as serialPort, and select the Protocol Type as FSK Module or RDC
Module to set uploading mode.