112
B. Input Types
Table B-1 Input Types
Input Types
Operations
Instant Zone
The system will immediately alarm when it detects triggering
event after system armed.
Audible Response Trigger the system sound and sounder.
Voice Prompt: Zone X alarm.
Perimeter Zone
The system will immediately alarm when it detects triggering
event after system armed.
Audible Response: Trigger the system sound and sounder.
There is a configurable interval between alarm and sounder
output, which allows you to check the alarm and cancel the
sounder output during the interval.
Voice Prompt: Zone X perimeter alarm.
Delayed Zone
The system provides you time to leave through or enter the
zone without alarm.
Audible Response: Trigger the system sound and sounder.
Voice Prompt: Zone X alarm.
Follow Zone
The zone acts as delayed zone when it detects triggering event
during system Entry Delay, while it acts as instant zone
otherwise.
Audible Response: Trigger the system sound and sounder.
Voice Prompt: Zone X follow alarm.
24H Silence Zone
The zone activates all the time without any sound/sounder
output when alarm occurs.
Audible Response: No system sound (voice prompt or
sounder).
Panic Zone
The zone activates all the time.
Audible Response: Trigger the system sound and sounder.
Voice Prompt: Zone X panic alarm.
Fire Zone
The zone activates all the time with sound/sounder output
when alarm occurs.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HIKVISION AX HYBRID PRO and is the answer not in the manual?

HIKVISION AX HYBRID PRO Specifications

General IconGeneral
BrandHIKVISION
ModelAX HYBRID PRO
CategorySecurity System
LanguageEnglish

Related product manuals