DS-K2600 Series Access Controller
18
No.
DS-K2604
D9
C3
Event Alarm Input3
D10
C2
Event Alarm Input 2
D11
GND
Grounding
D12
C1
Event Alarm Input 1
Notes:
The Alarm input hardware interface is normally open by default. So only the normally
open signal is allowed. It can be linked to the buzzer of the card reader and access
controller, and the alarm relay output and door relay open and close.
Arming region alarm input linkage is only for the alarm relay output linkage.
RS485 card ID should be set as 1to 8. For example, the ID of door 1 is 1 and 2 standing
for in and out respectively.
For single-door access controller, the Wiegand card reader 1 and 2 respectively
correspond to the entering and exiting card readers of door 1. For two-door access
controller, the Wiegand card reader 1 and 2 respectively correspond to the entering
and exiting card readers of door 1, and the Wiegand card reader 3 and 4 respectively
correspond to the entering and exiting card readers of door 2. For four-door access
controller, the Wiegand card reader 1, 2, 3 and 4 respectively correspond to the
entering card readers of door 1, 2, 3, and 4.