By default, the keyfob is in one-to-one mode. The keyfob's DIP switch is towards 1 (OFF). The
keyfob can control only one turnsle.
One-to-Many Mode
The keyfob's DIP switch is ON. In this mode, the keyfob can control mulple turnsles.
1. Power
o the turnsle.
2. Set the No.4 switch of the DIP Switch on the access control board to the ON side.
3. Power on the turnsle and it will enter the keyfob pairing mode.
4. Hold the Close buon for more than 10 seconds. Or pair turnsle and keyfob in the client
soware, see Manage Keyfob User of the user manual for more details.
The keyfob's indicator of the will ash twice if the pairing is completed.
5. Set the No.4 switch to OFF, and reboot the turnsle to take eect.
Note
Only one
turnsle can pair the keyfob. If mulple turnsles are in the pairing mode, the
keyfob will select only one of them to pair.
For details about DIP switch value and meaning, see Access Control Board UART Descripon .
6. Oponal: Go to System → User → Keyfob User on the remote control page of the client
soware to delete the keyfob.
5.2
Inialize Device
Steps
1. Set the No.8 switch of the DIP 2 Switch on the access control board to the ON side.
DS-K3Y411X Series Flap Barrier Quick Start Guide