EasyManuals Logo
Home>HIKVISION>Intercom System>DS-KD8103-E6

HIKVISION DS-KD8103-E6 User Manual

HIKVISION DS-KD8103-E6
4 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Hangzhou Hikvision Digital Technology CO.,Ltd. No.555 Qianmo Road, Binjiang District, Hangzhou 310052, China
D Series Door Staon
Diagram References
ENGLISH
Appearance
1
Low Illuminaon Supplement Light
Camera
LCD Display Screen
1 2 3
4
5 6
Keypad
Call Buon
Note: The appearance of the device vary according to different model. Refers to the actual device.
UD19918B
1
3
9
Call Center Buon 7 Microphone 8 Card Reading Area
Loudspeaker 10 TAMPER
DS-KD8103-E6
2
1
2
3
4
9
10
5
7
8
6
RES
GND
W1
W0
BZ
ERR
OK
TAMP
AO2-
AO2+
AO1-
AO1+
AIN4
AIN3
AIN2
AIN1
NO1
COM1
NC1
NO2
COM2
NC2
GND
RES
SEN1
BTN1
SEN2
BTN2
GND
485A+
485A-
GND
WIEGAND
12 VDC GND
LOCK1
LOCK2
ALARM OUT
ALARM IN
ALARM IN
LAN
RESERVED
POWER
RS485
1
2
3 4
Installaon
Before you begin:
Accessory
3
Terminal
2
1. Accessories that you need to prepare for installaon: gang box and mounng template.
2. Make sure the power supply meet the power requirements of the door staon (12 VDC, 1 A).
3. Make sure all the related equipment is power-off during the installaon.
4. Wire the cables before installaon.
The dimension of the gang box is: 404 mm(W) × 123 mm(H) × 47.5 mm(D).
The installaon hole should be larger than gang box. The suggested dimension of the installaon hole
is 404.5 mm(W) × 123.5 mm(H) × 48 mm(D).
Flush Mounng
1. Drill an installaon hole on the wall.
Note: The size of the hole should be larger than that of the gang box. The suggested dimension of the
installaon hole is 404.5 mm(W) × 123.5 mm(H) × 48 mm(D).
2. Insert the gang box into the hole and fix it with 4 PA4 screws. Make sure the edges of the gang box
align to the wall. Route the cables of the door staon through the cable hole.
3. Pull the door staon downward and then push it towards the inside to make sure it fits the hole.
4. Tighten the screws of the door staon with the Allen wrench.
NC1/NC2: Door Lock Relay Output (NC)
NO1/NO2: Door Lock Relay Output (NO)
COM1/COM2: Common Interface
DC 12 V: Power Supply Input
AO1+/AO1- : Alarm Relay Output 1
AO2+/AO2- : Alarm Relay Output 2
AIN1/AIN2/AIN3/AIN4: Alarm Input
SEN1/SEN2: Door Contact Detecon Input/Door Contact
BTN1/BTN2: Door Contact Detecon Input/Exit Buon
GND: Grounding
485A-: RS-485 Communicaon Terminal
485A+: RS-485 Communicaon Terminal
TAMP: Wiegand Card Reader TAMPER
OK: Card Reader Indicator Output (Valid)
ERR: Card Reader Indicator Output (Invaild)
BZ: Card Reader Buzzer Output
W0: Data Input Interface Wiegand Card Reader
W1: Data Input Interface Wiegand Card Reader
RES: Reserved
Note: Wiring descripon refers to the User Manual.
Call from Main/Sub Door Staon
Call from Outer Door Staon
Configuraon4
Acvate Device
1. Power on the device to enter the acvaon page automacally.
2. Create a password and confirm it.
3. Press # to acvate the door staon.
Note:
Enter an 8 to 16 characters admin password.
When entering the password, taking the numeric key 2 as example, press the numeric key 2 once, the text
field shows “2”, and press it again in 1.5 s, the text field shows “a”, and press it again in 1.5 s, the text field
shows “b”, and so on.
Hold 0 to enter special characters.
Press # to confirm the password.
Press * to delete the password during entering.
You are required to acvate the device first by seng a strong password for it before you can use the device.
1
Call Resident
The door staon can work as main/sub door staon, and outer door staon, which correspond to different
calling resident modes respecvely.
Press number buon to enter the calling page.
Enter the room No. and press call buon again to call.
2
Call Center
3
Press number buon to enter the calling page.
EnterBuilding No. + # + Unit No. + # + Room No. and press call buon to call resident.
Press number buon to enter the calling page.
Press center buon to call. Press * to cancel during calling management center.
Unlock by Entering Password
Unlock by Presenng Card
The device support unlock the door by presenng card, entering password, and fingerprint. Here
takes unlock by entering password and unlock by presenng card for example.
Note: You should create the password and add the card to the device first.
Common Password
Press number buon, enter# + room No. + password + # to unlock the door.
Public Password
Note: Create the public password via iVMS-4200 Client Soware remotely first.
Press number buon, enter# + public password + #to unlock the door.
Present the card on the card reading area to unlock the door.
Unlock Door
4
Refer to Video Intercom D Series Door Staon User Manual (scan the QR code) for details.
47.5
404
Unit : mm
123

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HIKVISION DS-KD8103-E6 and is the answer not in the manual?

HIKVISION DS-KD8103-E6 Specifications

General IconGeneral
Package depth205 mm
Package width195 mm
Package height525 mm
Package weight2166 g
Indoor unit included-
Outdoor unit includedYes
Megapixel2 MP
Supported video modes480p, 720p, 1080p
Viewing angle, vertical119 °
Maximum video resolution1920 x 1080 pixels
Viewing angle, horizontal72 °
Proper useOutdoor
Control typeButtons
Product colorBlack
International Protection (IP) codeIP65
Display diagonal3.5 \
Display resolution480 x 320 pixels
Display technologyLCD
LED typeIR
Number of buttons2 buttons
Connectivity technologyWired
Ethernet LAN data rates10, 100, 1000 Mbit/s
Ethernet interface typeGigabit Ethernet
Ethernet LAN (RJ-45) ports1
Supported network protocolsTCP/IP, RTSP
Operating temperature (T-T)-40 - 55 °C
Operating relative humidity (H-H)10 - 95 %
Outdoor unit power typeDC
Power consumption (typical)10 W
Weight and Dimensions IconWeight and Dimensions
Depth61 mm
Width145 mm
Height418 mm
Weight1050 g

Related product manuals