EasyManua.ls Logo

HIKVISION DS-PDC15-EG2-WE - User Manual

HIKVISION DS-PDC15-EG2-WE
7 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
©2020 Hangzhou Hikvision Digital Technology Co., Ltd. All rights reserved.
About this Manual
The Manual includes instrucons for using and managing the Product. Pictures, charts, images and all other informaon hereinaer are for descripon and explanaon only. The informaon contained in the Manual is subject to change,
without noce, due to firmware updates or other reasons. Please find the latest version of this Manual at the Hikvision website (hps://www.hikvision.com/).
Please use this Manual with the guidance and assistance of professionals trained in supporng the Product.
and other Hikvision's trademarks and logos are the properes of Hikvision in various jurisdicons. Other trademarks and logos menoned are the properes of their respecve owners.
Disclaimer
TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, THIS MANUAL AND THE PRODUCT DESCRIBED, WITH ITS HARDWARE, SOFTWARE AND FIRMWARE, ARE PROVIDED “AS IS” AND “WITH ALL FAULTS AND ERRORS”. HIKVISION MAKES
NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION, MERCHANTABILITY, SATISFACTORY QUALITY, OR FITNESS FOR A PARTICULAR PURPOSE. THE USE OF THE PRODUCT BY YOU IS AT YOUR OWN RISK. IN NO EVENT WILL
HIKVISION BE LIABLE TO YOU FOR ANY SPECIAL, CONSEQUENTIAL, INCIDENTAL, OR INDIRECT DAMAGES, INCLUDING, AMONG OTHERS, DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, OR LOSS OF DATA, CORRUPTION OF
SYSTEMS, OR LOSS OF DOCUMENTATION, WHETHER BASED ON BREACH OF CONTRACT, TORT (INCLUDING NEGLIGENCE), PRODUCT LIABILITY, OR OTHERWISE, IN CONNECTION WITH THE USE OF THE PRODUCT, EVEN IF HIKVISION HAS BEEN
ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR LOSS.
YOU ACKNOWLEDGE THAT THE NATURE OF INTERNET PROVIDES FOR INHERENT SECURITY RISKS, AND HIKVISION SHALL NOT TAKE ANY RESPONSIBILITIES FOR ABNORMAL OPERATION, PRIVACY LEAKAGE OR OTHER DAMAGES RESULTING FROM
CYBER-ATTACK, HACKER ATTACK, VIRUS INSPECTION, OR OTHER INTERNET SECURITY RISKS; HOWEVER, HIKVISION WILL PROVIDE TIMELY TECHNICAL SUPPORT IF REQUIRED.
YOU AGREE TO USE THIS PRODUCT IN COMPLIANCE WITH ALL APPLICABLE LAWS, AND YOU ARE SOLELY RESPONSIBLE FOR ENSURING THAT YOUR USE CONFORMS TO THE APPLICABLE LAW. ESPECIALLY, YOU ARE RESPONSIBLE, FOR USING THIS
PRODUCT IN A MANNER THAT DOES NOT INFRINGE ON THE RIGHTS OF THIRD PARTIES, INCLUDING WITHOUT LIMITATION, RIGHTS OF PUBLICITY, INTELLECTUAL PROPERTY RIGHTS, OR DATA PROTECTION AND OTHER PRIVACY RIGHTS. YOU
SHALL NOT USE THIS PRODUCT FOR ANY PROHIBITED END-USES, INCLUDING THE DEVELOPMENT OR PRODUCTION OF WEAPONS OF MASS DESTRUCTION, THE DEVELOPMENT OR PRODUCTION OF CHEMICAL OR BIOLOGICAL WEAPONS, ANY
ACTIVITIES IN THE CONTEXT RELATED TO ANY NUCLEAR EXPLOSIVE OR UNSAFE NUCLEAR FUEL-CYCLE, OR IN SUPPORT OF HUMAN RIGHTS ABUSES.
IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL AND THE APPLICABLE LAW, THE LATER PREVAILS.
1
Appearance
2
Enrollment
Note: The enrollment progress will be completed in 3 to 10 seconds normally.
1
Enroll the Peripheral Locally
1. Log in to the APP Store, download and install the App.
2. Power on the security control panel.
3. Log in the APP and tap the icon "+" . Scan the QR code or input the control panel serial No. to add the control panel.
1. In the APP, tap the "Enrollment Mode" buon on the control panel page to make the control panel enter the enrollment status.
2. Loosen the screw and remove rear panel.
3. Power on the peripheral, and it will be automacally enrolled to the control panel.
This product and - if applicable - the supplied accessories too are
marked with "CE" and comply therefore with the applicable harmonized
European standards listed under the EMC Direcve 2014/30/EU, RE
Direcve 2014/53/EU, the RoHS Direcve 2011/65/EU.
replacement of a baery with an incorrect type that can defeat a safeguard (for example, in the case of some lithium
baery types);
– disposal of a baery into fire or a hot oven, or mechanically crushing or cung of a baery, that can result in an
explosion;
– leaving a baery in an extremely high temperature surrounding environment that can
result in an explosion or the leakage of flammable liquid or gas; and
– a baery subjected to extremely low air pressure that may result in an explosion or the leakage of flammable liquid
or gas
2012/19/EU (WEEE direcve): Products marked with this symbol
cannot be disposed of as unsorted municipal waste in the European
Union. For proper recycling, return this product to your local supplier
upon the purchase of equivalent new equipment, or dispose of it at
designated collecon points. For more informaon see:
www.recyclethis.info
2006/66/EC (baery direcve): This product contains a baery that cannot be disposed of as unsorted municipal
waste in the European Union. See the product documentaon for specific baery informaon. The baery is marked
with this symbol, which may include leering to indicate cadmium (Cd), lead (Pb), or mercury (Hg). For proper
recycling, return the baery to your supplier or to a designated collecon point. For more informaon see:www.recy-
clethis.info
CAUTION
RISK OF EXPLOSION IF BATTERY
IS REPLACED BY AN INCORRECT
TYPE.
REPLACEMENT OF A BATTERY
WITH AN INCORRECT TYPE THAT
CAN DEFEAT A SAFEGUARD.
CAUTION
CHEMICAL BURNING DANGER
DO NOT SWALLOW THE
BATTERY
KEEP NEW AND USED
BATTERIES AWAY FROM THE
CHILDREN.
IF YOU THINK BATTERIES MIGHT
HAVE BEEN SWALLOWED OR
PLACED INSIDE ANY PART OF
THE BODY, SEEK IMMEDIATE
MEDICAL ATTENTION.
CAUTION
DISPOSE OF USED BATTERIES
ACCORDING TO THE INSTRUC-
TIONS AND LOCAL REGULATION.
xxxx
Enrollment Mode
CAUTION
IF THE BATTERY COMPARTMENT
DOES NOT CLOSE SECURELY,
STOP USING THE PRODUCT AND
KEEP IT AWAY FROM CHILDREN.
Indicator
Bracket Tamper Port
Baery
Tamper Switch
Power Switch
7 T i m e s
Wireless Curtain Detector
DS-PDC15-EG2-WE
EN 50131-1:2006+A2:2017
EN 50131-2-2:2017
EN 50131-5-3:2017
Security Grade(SG) 2
Environmental Class(EC) II
Cerfied by Teleficaon
1
Hangzhou Hikvision Digital Technology CO.,Ltd. No.555 Qianmo Road, Binjiang District, Hangzhou 310052, China
Question and Answer IconNeed help?

Do you have a question about the HIKVISION DS-PDC15-EG2-WE and is the answer not in the manual?

Overview

The Hikvision DS-PDC15-EG2-WE is a wireless curtain detector designed for security applications. This device is certified with Security Grade 2 and Environmental Class II, ensuring reliable performance in various indoor environments. The detector's primary function is to identify intrusions by sensing movement within a defined curtain-shaped detection zone, providing an early warning system for protected areas.

Function Description

The DS-PDC15-EG2-WE operates as a perimeter security device, creating an invisible curtain of detection that is ideal for protecting windows, doors, or specific narrow passages. When an intruder crosses this curtain, the detector triggers an alarm, sending a notification to a connected security control panel. The device utilizes advanced digital microprocessor-based technology to ensure accurate detection and minimize false alarms. It features auto-sensitivity and digital temperature compensation, allowing it to adapt to changing environmental conditions and maintain consistent performance. The sealed optics and direct light filter (up to 6500lux) enhance its reliability by preventing interference from external light sources.

The detector supports two-way wireless communication, ensuring a secure and stable connection with the control panel. It employs frequency hopping and AES-128 encryption for robust data transmission, protecting against signal jamming and unauthorized access. The device includes a tamper protection mechanism for both the front and back panels, which triggers an alarm if anyone attempts to open or remove the detector from its installed position. An LED indicator, which illuminates blue during an alarm, provides visual feedback on the device's status.

The DS-PDC15-EG2-WE offers flexible configuration options through a dedicated mobile application. Users can select different zone types, enable or disable a "Stay Arm Bypass" feature to exclude the zone during stay arming, and activate a chime function for audible alerts. It also supports an "Enable Silent Zone" mode, where the zone remains silent when an alarm is triggered. Advanced features like "Double Knock" require two detections within a short period to trigger an alarm, reducing false positives. The "Cross Zone" feature allows for the linking of two zones, reporting an alarm only if both are triggered within a set timeframe, further enhancing accuracy.

Users can adjust the detector's sensitivity, with higher sensitivity making it easier to detect intruders. The device can capture images, and users can set the image resolution and the number of images captured in a series. Other configurable parameters include the "Swinger limit activation," which sets the limit for swinger activity, and the "Trigger Interval," which defines the time between consecutive triggers to prevent repeated alarm messages. The LED indicator can be turned on or off, and the "Polling Rate" can be set to define the heartbeat interval. The device also includes "Signal Strength Test" and "Detection Zone Test" modes to assist with installation and ensure optimal performance. A "Zone Bypass" function allows users to temporarily bypass a zone, and a "Capture" function enables manual picture capture.

Usage Features

The DS-PDC15-EG2-WE is designed for straightforward enrollment and installation. The enrollment process can be completed locally or by scanning a QR code or inputting the serial number via the mobile application. Once enrolled, the device automatically connects to the control panel. For re-enrollment, users need to hold the tamper button, power off the device, and then power it back on.

Installation involves securing the rear panel to a wall using four screws after knocking out the screw holes. Alternatively, the device can be mounted using sponge tape, though this method is not EN compliant. Optional wall and ceiling bracket accessories are available for flexible mounting. The installation height is recommended to be between 1.8 to 3 meters to achieve the optimal detection range of 15 meters with a 6.3° angle, covering 18 zones and 8 planes.

After installation, it is crucial to check the signal strength and installation environment. The device enters a walk test mode for 3 minutes after enrollment. During this mode, triggering the detector within its detection range will cause the LED indicator to turn blue if the installation position is proper. If the LED remains off, the detector's position needs adjustment. Signal strength can be checked via the control panel, with solid green indicating a strong signal, solid orange a medium signal, solid red a weak signal, and red flashes indicating a failure.

The device is powered by a CR123A battery, which provides a standard battery life of 5 years. The low voltage value is 2.45 V, and the device includes a battery compartment that must close securely to prevent chemical burning danger.

Maintenance Features

Proper operation and maintenance are essential for the longevity and reliability of the DS-PDC15-EG2-WE. All electronic operations must comply with local electrical safety regulations and fire prevention guidelines. The device should not be dropped or subjected to physical shock, nor exposed to high electromagnetism radiation. Installation on vibrating surfaces or places subject to shock should be avoided to prevent equipment damage.

Before wiring, installing, or dismantling the device, ensure that the power has been disconnected. If any smoke, odors, or noise emanate from the device, immediately turn off the power, unplug the power cable, and contact the service center. The detector should not be placed in extremely hot, cold, dusty, or damp locations. It is designed for indoor use and must be kept away from rain and moisture. Direct sunlight, low ventilation, or heat sources like heaters or radiators should be avoided to prevent fire hazards.

The device should not be aimed at the sun or overly bright places, as this can cause blooming or smearing, affecting the sensor's endurance. Improper use or replacement of the battery can result in an explosion hazard. Always replace the battery with the same or an equivalent type and dispose of used batteries according to the manufacturer's instructions and local regulations. The device should not be exposed to corrosive gas or explosive situations, as these can cause equipment damage. Regular checks of the battery compartment's secure closure are important, especially to keep batteries away from children. If batteries are suspected to have been swallowed or placed inside any part of the body, immediate medical attention should be sought.

HIKVISION DS-PDC15-EG2-WE Specifications

General IconGeneral
ModelDS-PDC15-EG2-WE
CategorySecurity Sensors
Detection Range15 m
Detection Angle90°
Wireless Frequency868 MHz
Battery Life3 Years
Protection LevelIP65
TypePIR Motion Detector
Battery TypeCR123A
Operating Temperature-10 °C to 55 °C
Operating HumidityUp to 95% (non-condensing)
Power SupplyBattery