HIKVISION DS-PHA64-LP/NP - Automation Configuration

HIKVISION DS-PHA64-LP/NP
134 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
29
4. Set the relay name.
5. Select the linked area.
Note
Only enabled areas will be listed.
The newly added peripheral is linked to area 1 by default.
The function varies according to different relay types
6. Set event type and its parameters:
Secondary Event
The sub-event type of alarm, arm, disarm and fault event.
Activation Mode
Latched: Continue the output until the relay is manually closed or opened.
Pulsed: The relay will be closed/open after the set duration.
Contact Status
Normally Open: Under normal conditions, the relay is open. When the event is triggered, the
relay will be closed.
Normally Closed: Under normal conditions, the relay is closed. When the event is triggered,
the relay will be open.
Schedule
You can set the close/open time for the relay.