EasyManuals Logo

HIKVISION HWD-5108H User Manual

HIKVISION HWD-5108H
210 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #121 background imageLoading...
Page #121 background image
Digital Video Recorder User Manual
120
Figure 8-9 Set PTZ Linking of Alarm Input
Step 15 If you want to set handling action of another alarm input, repeat the above steps or just
copy the above settings to it.
Figure 8-10 Copy Settings of Alarm Input
Step 16 (Optional) Enable the one-key disarming for local alarm input 1 (Local<-1).
1) Check the checkbox of Enable One-Key Disarming.
2) Click the Settings button to enter the linkage action settings interface.
3) Select the alarm linkage action (s) you want to disarm for the local alarm input 1. The
selected linkage actions include the Full Screen Monitoring, Audible Warning, Notify
Surveillance Center, Send Email and Trigger Alarm Output.

Table of Contents

Other manuals for HIKVISION HWD-5108H

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HIKVISION HWD-5108H and is the answer not in the manual?

HIKVISION HWD-5108H Specifications

General IconGeneral
BrandHIKVISION
ModelHWD-5108H
CategorySecurity Camera
LanguageEnglish

Related product manuals