EURO 46 V10 Programming Manual
Engineer Menu Sub-Menu
Defaults
2000 2002 Differences
Guard Code Alarm [03] (minutes)
Fire Siren Time [99] (minutes)
Set Fail Warning [00] (minutes)
Input NAT Days [14] (days)
Input NAT Hours [00] (hours)
Wireless Supervision Time [02] (hours)
Wireless Jamming Time [100] (seconds)
Service Time [000] (days)
CODES AND USERS? 5 digit PINs? Yes [1] No [0]
Change Duress Codes? 1: Guard/Duress, 2-9: Empty, 10: Code
Change Master Manager
Code
2222
User Areas [01ABCD]
User Set Options Unset / Set [0]
Flexi Set Yes [1]
User Name _
Change Engineer Code 1111
VOLUME CONTROL Entry [4]
Exit [4]
APP Exit [4]
Alarm [7]
Fire [7]
Tamper [6]
Day Alarm [6]
Chime [3]
Intelligent Set [1]
Code Stops Sound Yes [1]
E/E Keypads Only No [0]
Alert Kps Only Yes [1]
Silent Tech Alert No [0]
SYSTEM OPTIONS Site Options?
Set with Fault Yes [1]
Set with Tamper No [0] Yes [1]
Set with ATS Fault No [0] Yes [1]
Set Ward T(Tech)Fault Yes [1]
Set Fail = Alarm No [0]
Do Bat Load Test No [0]
Strobe/Sqwk At Set None [0]
Re-Arm Omits No [0]
Use Level Set No [0]