Error Code List
© 2009 Hirschmann Automation and Control GmbH · Branch Office Ettlingen · eMail: info.ecs@hirschmann.de · www.hirschmann.com 22
24 183 69 1012e (Generic) / 2009-02-26 / Rev. 01 / rk.
Error Code Error Cause Elimination
E32
Error in the power
supply
• +UB System not present at the
system start
• +UB System not present at the
system finish
• Contact problems at +UB
switch off/on
• +UB System and +UB Power
must be wired separately: +UB
System connected direct with
the crane battery. +UB Power
for switch on/off
• +UB switch off/on again
E37
Error in the logical
program flow
• System program file is
defective
• Flash-EPROM defective
• Upload valid system software
• Replace central unit
E38
System program and
crane data file do not
match.
• The system program in the LMI
does not match to the
programming in the crane data
file
• Upload valid system program
file or the valid crane data file
E39
System program and
load chart file do not
match
• The system program in the LMI
and the programming in the
load chart file do not match.
• Upload valid system program
file or the valid load chart file
E43
Error in the write/read
memory, (RAM)
• Write/read memory (RAM) or
central unit defective.
• Replace central unit
E47
Error in the monitored
write/ read memory.
The CRC verification of
the monitored write/read
memory provides an
incoherent result
• The CRC sign of the monitored
write/read memory is wrong
• The buffer battery is decharged
(< 2V at 1kOhm).
• Central unit defective.
• Restart the LMI
• Replace buffer battery on the
central unit.
• Replace central unit
E51
Error in the crane data
file
• No valid data in the crane data
file.
• Flash-EPROM defective
• Upload valid crane data file
• Replace central unit
E52
Error in load chart file.
• No valid data in the load chart
file
• Flash-EPROM defective
• Upload valid load chart file
• Replace central unit
E53
Wrong setup of min.
analog inputs length1,
angle1, pressure1
• Analog input not supported • Setup correct Flag in in DGA
6.i.2
E56
Error in crane data file.
• No valid data in the crane data
file during calibration.
• Flash-EPROM defective
• Restore or upload valid crane
data file
• Replace central unit
E57
Error in serial crane
data file.
• Calibration data file does not
contain valid data.
• Flash-EPROM defective
• Upload calibration data file by
changing data (OM, limits) and
save
• Replace central unit
• CAN Bus cable between the
central unit and the sensor unit
defective or not connected.
• Check the connection between
the central unit and the sensor
units
E61
Error in the CAN bus
data transfer for all CAN
units
• Can bus port in the central unit
defective
• Replace the central unit