Sensor Calibration
© 2009 Hirschmann Automation and Control GmbH · Branch Office Ettlingen · eMail: info.ecs@hirschmann.de · www.hirschmann.com 14
24 183 69 1012e (Generic) / 2009-02-26 / Rev. 01 / rk.
3.4 Angle sensor calibration procedure
The angle sensor can be calibrated for its zero point, with steep boom (75°) and one or two additional
angle values (40° / 65°)
Material required: calibrated inclinometer
Start screen adjustment, boom angle:
leave the service menu
Start angle calibration procedure
Start calibration for "zero degree" angle:
leave the service menu
skip calibration step / go to next menu